Town of Pembroke Park

Broward County · Florida ← All authorities

Town of Pembroke Park

Broward County

Verified Aug. 5, 2026

Town of Pembroke Park is a town authority in the State of Florida, serving 6,260 residents. This page is the permit route for that jurisdiction: the fifteen steps from working out who has a say over an address through to permission to operate, the documents this authority publishes, and 62 answers taken from those documents and dated.

Jurisdiction & key facts

The standing 62-question set, answered for Town of Pembroke Park against this authority’s own published documents. Every answer carries the confidence it was recorded at and the document it came from. Where nothing is published we say so and show where we looked — a blank here is a finding, not a gap.

Town of Pembroke Park is the authority having jurisdiction 94% confidence
Holds
building, electrical, plumbing, mechanical, zoning/planning, engineering and floodplain - permitting, plan review and inspection, all in-house
Overridden by
Broward County Board of Rules and Appeals writes the administrative code: its codified amendments to Florida Building Code Chapter 1 (Municode clientId 12263, product 15755, effective through 30 March 2026) are adopted verbatim by Town Code Sec. 5-16 and supply the dedicated photovoltaic plan-review lists (Sec. 107.3.5 A.14 structural, B.19 electrical) and the dedicated photovoltaic inspection sequence (Sec. 110.3 building item 20, electrical item 10), the permit-life rules, the PE thresholds and the Florida Product Approval filing duty. Contractor licensing is Broward County (Certificate of Competency). Fire rescue is contracted to the Broward Sheriff's Office (BSO Station 27). Interconnection is FPL's under FL PSC Rule 25-6.065. FS 553.791 private-provider review is available at the owner's election.
Why not higher
The Town is NOT the contract community the brief hypothesised. Its FY2026 Adopted Budget states in words 'Building is fully staffed with 6 employees and 0 opens. Any additional services will be contracted out' and, town-wide, 'Town is fully staffed' with 'Contractors now represent less than 35% of total town expenses vs. 62% in 2019'. The Building Fund is a separate special revenue fund carrying a full personnel stack (Compensation $476,997, payroll taxes $38,160, employee insurance $84,231, retirement $66,923) against Contractual Services of $199,323 - 20%, not the 75-100% pass-through signature seen at Southwest Ranches, West Park or Perry. The FS 553.80(7)(b) report independently shows a personnel line of $433,997.41 and 7 dedicated personnel. Two caveats keep this at 94 rather than 96: the staff directory names a Chief Building Official, a Building Facilities Manager, a Permit Technician, a BTR Clerk and a Code Compliance Clerk but NO inspector and NO plans examiner, and the Town Planner is listed without a name - so the trade disciplines and planning are very likely bought in under that Contractual Services line; and the FS 553.80 report's 'Operating expenditures and expenses $1,130,461.40' cannot be reconciled with a Building Fund whose entire FY2026 budget is $992,311, so the two instruments disagree.

https://www.tppfl.gov/DocumentCenter/View/704/2025-2026-Adopted-Budget

Permit required
Yes. The Town's own Solar Panels Application Checklist opens: 'The installation, replacement or major repair of a Solar Panel (photovoltaic) requires a Permit be issued.' Separately,97%
Permit cost
No solar-specific fee line exists. Under the published schedule a residential PV permit is built up per discipline as: minimum permit fee $75 per discipline for work valued to $1,000,62%
Plan review
15 working days for the Building Department's written approval or denial, EXCLUDING Planning and Zoning, Engineering and Fire review.85%
Portal
Gov-Easy (apps.gov-easy.com, clientId d60f9827-2c53-44a4-9037-31e1de2b3f09) for permit/inspection lookup and payment,93%
Electrical code
NEC 2020 (NFPA 70-2020), in force through the Florida Building Code 8th Edition (2023), effective 31 December 2023.90%
Own placard wording
No. The Town specifies no placard wording of its own. 'Solar' appears exactly ONCE in the Town's entire 4.27 MB codified corpus and the hit is 'solariums' in a Chapter 15 list of businesses…85%
Booking an inspection
Email, or phone. The Town instructs 'You must email permits@tppfl.gov to... Request Inspections'.88%
Permitting 5 steps · 28 questions

Whether a permit is needed — Yes. The Town's own Solar Panels Application Checklist opens: 'The installation, replacement or major repair of a Solar Panel (photovoltaic) requires a Permit be… Q3 Electrical and building permits — Separate, and at least two of them. The Broward County Uniform Building Permit Application (Revised 01-08-2026, Q4 Plan review — 15 working days for the Building Department's written approval or denial, EXCLUDING Planning and Zoning, Engineering and Fire review. Q18 Where you file — Gov-Easy (apps.gov-easy.com, clientId d60f9827-2c53-44a4-9037-31e1de2b3f09) for permit/inspection lookup and payment, Q20

Permit required
Yes. The Town's own Solar Panels Application Checklist opens: 'The installation, replacement or major repair of a Solar Panel (photovoltaic) requires a Permit be issued.' Separately,97% source
What it costs
No solar-specific fee line exists. Under the published schedule a residential PV permit is built up per discipline as: minimum permit fee $75 per discipline for work valued to $1,000,62% source
Plan review turnaround
15 working days for the Building Department's written approval or denial, EXCLUDING Planning and Zoning, Engineering and Fire review.85% source
Key document
submittal checklist + county code cited by 6 open the document
  1. Confirm who has a say over your address

    A city address is usually permitted by the city, not the county — but not always, and some authorities keep building and hand electrical to someone else. Getting this wrong costs the whole submittal, because every requirement below belongs to whoever actually holds jurisdiction. Check the overlays in the same pass: an HOA, a historic district, a windstorm certification or a system-size cap can reshape the design, and all of them are cheaper to find now than after the array is laid out.

    • Is this authority the AHJ for residential solar at this address? Yes. The Town of Pembroke Park (Broward County, pop. ~6,260, entirely inside the High Velocity Hurricane Zone) is the AHJ for residential rooftop PV inside its limits. It runs an in-house Building Department - Chief Building Official Emmanuel Agbenohevi - that issues building, electrical, plumbing, mechanical, zoning and floodplain permits and performs its own inspections. It is NOT a contract community: the FY2026 Adopted Budget states 'Building is fully staffed with 6 employees and 0 opens' and 'Town is fully staffed'. 96% · department page + adopted budget + FS 553.80(7)(b) report
    • What does this authority permit itself, and what does it delegate? Both, and more: the Town permits and inspects Building, Electrical, Plumbing, Mechanical, Zoning/Planning, Engineering and Floodplain itself. Three things sit elsewhere - (a) contractor LICENSING is Broward County (State Registration & Broward County Certificate of Competency), (b) FIRE RESCUE is contracted to the Broward Sheriff's Office (BSO Fire Station 27, 2610 SW 40th Avenue), and (c) the administrative code (FBC Chapter 1) is Broward County's, written by the Broward County Board of Rules and Appeals and adopted verbatim by Town Code Sec. 5-16. 92% · adopting ordinance + department forms
    • Is a permit required for a residential rooftop PV system? Yes. The Town's own Solar Panels Application Checklist opens: 'The installation, replacement or major repair of a Solar Panel (photovoltaic) requires a Permit be issued.' Separately, BORA Board Policy 22-03 (the Mandatory Countywide Rooftop Mounted Equipment Affidavit, effective 24 Oct 2022, revised 17 Nov 2022), which the Town publishes and requires with every HVHZ roofing permit, states 'PERMITS ARE REQUIRED FOR: REMOVAL AND REINSTALLATION OF PHOTOVOLTAIC PANELS.' 97% · published submittal checklist
    • Is there a separate electrical permit, or is it combined? Separate, and at least two of them. The Broward County Uniform Building Permit Application (Revised 01-08-2026, effective 03-09-2026) is a one-trade-per-form document ('Select One Trade: Building / Electrical / Plumbing / Mechanical / Other') and its owner's affidavit reads 'I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS'. The Solar Panels Application Checklist requires a Broward County Uniform Permit Application with Structural checked AND one with Electrical checked AND (for thermal/hybrid) one with Plumbing checked, plus a separate zoning Review Application. 95% · permit application + submittal checklist
    • Is a HOA or architectural approval required first? Yes, and it is codified and mandatory - one of the strongest association gates found in this survey. Town Code Sec. 5-28: 'All building permit applications for real property located on land which is subject to legally binding covenants, conditions, rules or regulations of a property association such as a homeowners association, condominium association, or co-operative association must be co-signed by the property owner and the manager or officer of the property association prior to the issuance of any building permit.' Sec. 5-29 then makes the association responsible for ensuring the permitted work is completed in compliance. The Solar Panels Application Checklist independently requires an 'Association approval letter for the scope of work performed.' 94% · ordinance + submittal checklist
    • Is there a historic-district review? No. There is no historic-district review in Pembroke Park. 'Certificate of appropriateness' returns ZERO hits across the whole codified corpus; there is no historic preservation board, no design review board and no architectural review board in Chapter 2 (Administration, all thirteen articles recovered) or Chapter 28 (Zoning, all nine articles and all fifteen district divisions recovered). The only 'historic' machinery in the code is the flood ordinance's historic-building variance at Sec. 10-61. 88% · code of ordinances (full-corpus search)
    • Is a wind or windstorm certification required? Not a 'windstorm certification' as such - Florida Product Approval, filed before installation, plus wind evidence in the drawings. Broward FBC Ch.1 107.3.5.4: 'Product approvals shall be reviewed and approved by the building designer prior to submittal... Product approval shall be filed with the Building Official for review and approval prior to installation.' The PV plan-review list requires (d) 'Wind resistance ratings of modules', (e) 'Roof live load approval', (f) 'Fire classification of buildings and modules' and (h) 'Design load path'. The Town's checklist requires 'attachment details, flashing details, construction design for the unit and any supporting frame members (sealed by the appropriate design professional) for the Wind Zone, additional loading, and any site conditions.' NO WIND SPEED IN MPH IS STATED ANYWHERE in either corpus. 87% · county code (FBC Ch.1 amendments)
    • Is a Specific Use Permit or Council approval ever required? No. A rooftop PV array needs no special exception, variance or Town Commission approval. Chapter 28 Article IV (Supplemental District Regulations, 41 docs) and Article V (Non-conforming uses) were read in full and neither lists solar; the Special Exception and Variance application checklists on the Town Planner's page are triggered by use and dimensional relief, not by equipment. A zoning Review Application IS required with every PV submittal, but that is a staff-level review, not a hearing. 72% · code of ordinances (full-corpus search)
    • Is there a system-size cap on residential generation? No Town-level cap. The binding limits are FPL's: net metering tiers are Tier 1 up to and including 10 kW AC, Tier 2 over 10 kW to 100 kW, Tier 3 over 100 kW to 2 MW; and 'Customer generation is limited to 90 percent of the FPL distribution service rating (Transformer).' Crossing 10 kW AC moves a residential job from Tier 1 into Tier 2 and triggers the mandatory visually-open DER disconnect switch (see Q48), so 10 kW AC is the number that changes the job. 80% · utility DG manual + code absence
  2. Check who is allowed to apply

    Several authorities require the electrical permit to be pulled by a licensed electrician, or require the contractor to be registered with them BEFORE applying. Registration is not same-day. This is second on the list rather than fourth because it is the step most likely to stop the job before the drawings matter.

    • Who is allowed to pull the electrical permit? Licensed electrician for the electrical permit, building/solar contractor for the building permit. The Solar Panels Application Checklist says, verbatim: 'Solar Contractors (PV) may obtain the Building permit in either Solar Thermal or Photovoltaic systems. Plumbing Contractors may obtain the master permit in the Solar Thermal category. Electrical Contractors may obtain the Electrical permit in the Photovoltaic category, being that a building contractor shall obtain the Building permit for the installation of the panels.' 93% · published submittal checklist
    • Must the contractor be registered with this authority before applying? Yes, and it is a hard gate. The Building Department page states 'Each contractor must register with the Town, showing proof of their qualifications prior to obtaining a permit for construction.' The Contractors Registration Form repeats it: 'In order for contractors to obtain permit from the Town of Pembroke Park, they Must register with the building Division.' Required with the form: Qualifier's driver's licence, workers' compensation or exemption, State Registration AND Broward County Certificate of Competency, business tax receipt, State certification licence, and a general liability certificate that must name the Town of Pembroke Park as Certificate Holder. 95% · department page + registration form
    • Is a homeowner permitted to self-install and self-permit? Yes, but only at a single-family residence or a duplex. The Solar Panels Application Checklist states 'Owner/Builder applications can only be accepted for single family residences and duplex as per FS 489.103.7.a', and the same checklist requires an owner-builder to provide 'the list of labor (the cost of the standard labor must be included) and materials' in place of a signed contract. The Broward County Uniform Building Permit Application carries an Owner-Builder box and a 'License Exempted per F.S. 489.117(4)(a)1' box. 90% · published submittal checklist
  3. Build the submittal package

    Almost everywhere wants a site plan, a one-line or three-line electrical diagram, equipment cut sheets with listings, and a structural attachment detail. Build it against the published checklist rather than the last jurisdiction you worked in — the checklist is what the reviewer marks against.

    • What documents make up a complete submittal? A complete PV submittal here is: (1) Broward County Uniform Permit Application, Structural checked, from a licensed contractor; (2) the same application, Electrical checked; (3) a zoning Review Application; (4) survey or site plan showing the location and extension of the work; (5) association approval letter for the scope of work; (6) signed and sealed drawings by a Licensed Engineer/Architect - a roof plan to scale showing panel locations, an electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter disconnect, grounding and the AC connection to the building; specification sheets with listings of all components and installation manuals for PV modules, inverter(s), combiner box, disconnect and mounting system; attachment details, flashing details and the construction design for the unit and any supporting frame members sealed by the appropriate design professional for the Wind Zone, additional loading and site conditions; for battery backup a summary of all standby loads with power ratings and estimated daily energy consumption; and electrical calculations showing wire sizing by ampacity, conduit fill and ambient derating; (7) EITHER a Florida Solar Energy Center (FSEC) System Approval Report OR signed and sealed engineered drawings; (8) Special Inspector Form if there are connections for truss anchorage; (9) a signed contract stating the value of the scope of work; (10) a recorded Notice of Commencement if the contract price exceeds $2,500; and (11) a Building Department Document Transmittal Form, without which a submittal 'will be returned without further processing'. 92% · published submittal checklist
    • How many copies, and in what format? Electronic, by email to permits@tppfl.gov, with a Building Department Transmittal Form (BDTF) on top of every package. The Town states: 'All Submissions require a Building Department Transmittal Form (BDTF). Any Submissions missing a BDTF will be returned without further processing.' Permit revisions, shop drawings and deferred engineering submittals additionally require their own Broward County Uniform Building Application. No copy count is published. 85% · department page
    • Is a site plan required, and what must it show? Yes. Two instruments require it. The Town's checklist: 'Survey or Site Plan showing the location and extension of the proposed work' plus a scaled Roof Plan 'indicating the location of the solar panels installation on the roof'. Broward's codified FBC Chapter 1, Sec. 107.3.5 building plan-review item A.14 'Photovoltaic' opens with (a) Site plan. The Broward application form itself also demands Flood Zn and BFE on its face, so the site plan has to carry flood data on any lot in a special flood hazard area. 92% · county code + submittal checklist
    • Is a one-line / three-line diagram required? Yes - and Broward asks for a THREE-line diagram, not a one-line. Codified FBC Chapter 1 Sec. 107.3.5 electrical plan-review item B.19 'Photovoltaic' lists: (a) Layout plan including combiner box and accessible junction boxes; (b) Size of system number of modules; (c) Wire size at the coldest temperature; (d) Listing and model numbers of all equipment and racking; (e) Inverter rating and location; (f) Three-line diagram; (g) Connection to utility line side or load side Busbar ratings; (h) Grounding; (i) Labeling. The Town's own checklist requires an 'Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter disconnect, grounding, required signed and AC connection to building.' 93% · county code (FBC Ch.1 amendments)
    • Are string and conductor calculations required? Yes. The Town's checklist requires 'Electrical calculations showing that all wire sizing has been determined with proper ampacity, conduit fill and ambient derating factors.' Broward's electrical plan-review item B.19(c) independently requires 'Wire size at the coldest temperature' and B.19(g) 'Connection to utility line side or load side Busbar ratings'. 93% · submittal checklist + county code
    • Is a structural PE stamp required, and at what threshold? Signed and sealed drawings by a Licensed Engineer or Architect are required for a PV job here - BUT the Town's checklist offers a genuine alternative: 'Choose one of the following: Florida Solar Energy Center (FSEC) System Approval Report - All solar systems drawings shall be accompanies with a FSEC Approval report --- OR --- Signed and Sealed Engineered Drawings'. County-side, Broward FBC Ch.1 107.3.4.0.3 requires a PE where work 'involves extensive computation based on structural stresses'; 107.3.4.0.6 lets the Building Official require a PE 'for any work involving structural design, regardless of the cost'; and 107.3.5.2.1 requires whole-building structural calculations for Group R3 with an Exception for 'Component systems covered by product approval or designed by a delegated professional' - which is the racking product approval. A Special Inspector Form is additionally required 'if there are connections for truss anchorage'. 85% · submittal checklist + county code
    • Is an electrical PE stamp required, and at what threshold? Only above a threshold, and it is Broward's. FBC Ch.1 107.3.4.0.7: electrical plans must be prepared by a Professional Engineer for 'Residential systems requiring an aggregate electrical service capacity of more than 600 amperes or more than 240 volts' or where 'An electrical system having a cost value greater than one hundred twenty-five thousand dollars ($125,000.00)'. A normal residential PV job clears neither, so no electrical PE stamp. 90% · county code (FBC Ch.1 amendments)
  4. Apply and pay

    Most authorities now take the whole application through a portal, and several states cap or constrain what a residential solar permit may cost. Check whether plan check is billed separately before you quote the job.

    • Which permit portal does this authority use? Gov-Easy (apps.gov-easy.com, clientId d60f9827-2c53-44a4-9037-31e1de2b3f09) for permit/inspection lookup and payment, and Broward County ePermits OneStop (dpep.broward.org) for the county-level approvals a job may need first - Asbestos Certificate, Transportation Concurrency and Environmental Review, and Notice of Commencement. A new system is being brought in: the Town says it is 'currently updating all forms and transitioning to a New Online Permitting System'. 93% · portal landing page
    • Can the whole application be completed online? No - and the Town says so in bold on its own page. 'At this time, the GOV-EASY system does NOT provide notifications to staff for any self-submissions, scheduled inspections, or payments. You must email permits@tppfl.gov to: Request the most Current Versions; Submit Applications, Forms, and Required Documents; Request Inspections; Request Link To Make Payments.' The portal still works for viewing permit status and paying fees (card only, 3% processing fee, application/process number required). 95% · department page
    • What does a residential solar permit cost? No solar-specific fee line exists. Under the published schedule a residential PV permit is built up per discipline as: minimum permit fee $75 per discipline for work valued to $1,000, then 1.5% of value (residential, NON-cumulative) from $1,001 to $1,000,000; plus a $50 processing fee; plus a $45 flat residential plan review fee per discipline; plus an upfront inspection fee of $150 covering the first three inspections per discipline with $50 per additional inspection; plus a $35 Certificate of Completion; plus County and State surcharges; plus a 3% technology fee if paid by card. A $25,000 two-discipline (Building + Electrical) job therefore lands in the order of $900-$1,100 all-in, depending on how the Building Official apportions value between disciplines. 62% · fee schedule (FY2020-21)
    • How is the fee calculated? Valuation, with flat adders. Residential: 1.5% of job value, expressly NON-cumulative (commercial is cumulative and tiered 2.0%/1.5%/1.0%); minimum $75 per discipline for work up to $1,000. Valuation is set under FBC-BCAP 109.3 and 109.3.1 - the applicant states a value, the Building Official may demand RS Means or a signed contract, and 'Final building permit valuation shall be set by the Building Official.' Flat adders: $50 processing, $45 residential plan review per discipline, $150 upfront inspection per discipline, $35 CC, 3% card technology fee. 80% · fee schedule (FY2020-21)
    • Is there a separate plan-check fee? Yes. 'PLAN REVIEW FEES: Initial review fee charged on ALL applications (per discipline)' - residential $45 flat. Subsequent reviews: second and third review $45 flat each if comments are not cleared; 4th and subsequent disapprovals $180 (4x the first disapproval fee). Pre-plan/dry-run review $45 flat; expedited plan review $45 flat. 80% · fee schedule (FY2020-21)
  5. Plan review — and start the utility in parallel

    Interconnection is a separate process from the permit and usually the longer pole. Where the utility does not depend on the permit being issued, running both at once is the single biggest saving available on a residential job.

    • What is the stated plan-review turnaround? 15 working days for the Building Department's written approval or denial, EXCLUDING Planning and Zoning, Engineering and Fire review. The Building Department FAQ states: 'The Code allows a period of 15 working days to provide a written answer by either approving or denying an application. This period does not include review time for Planning and Zoning, Engineering, and Fire Departments.' Broward FBC Ch.1 105.3.1.6 supplies the statutory clock behind it: a local government may not request additional information more than three times without a written waiver; where the applicant responds within 30 days the government must act within 15 days, and after a second request within 10 days. 85% · department FAQ + county code
    • How long is an issued permit valid before it expires? 180 days to commence, then 90 days of abandonment kills it. Town Code Sec. 5-18 defers entirely to the FBC: 'The expiration of all issued permits shall be subject to the requirements set forth in Section 105.3.2 of the Florida Building Code.' Broward's 105.3.2.1: a permit becomes null and void if work is not commenced within 180 days of issue, or if work is suspended or abandoned for 90 days after commencement. 105.3.2.2: the Building Official may extend for no more than two 90-day periods, not to exceed one year from the initial expiration. Separately, an unpurchased APPLICATION goes void 60 days after notification (105.3.1.1), extendable once by 60 days on a written request made before expiry. 92% · ordinance + county code
    • Which utility handles interconnection here? Florida Power & Light Company (FPL), an investor-owned utility under FL PSC jurisdiction. 95% · codified franchise + Town-published utility document
    • Where does the utility sit in the sequence? Parallel, with a hard utility gate at the end. FPL's Electric Service Standards Section XIII: 'It is highly recommended that customers obtain FPL's written interconnection approval prior to procuring any material' and 'All net metering systems require written approval and agreement from FPL.' On the AHJ side, Broward FBC Ch.1 Sec. 110.3 B.11 makes the electrical final the moment the structure is 'deemed safe for power by the Building Official', and the final electrical inspection must precede the final structural inspection. So: apply to FPL and to the Town in parallel; FPL's written agreement and the Town's electrical final both have to land before the system energises. 78% · utility DG manual + county code

28 questions answered against Town of Pembroke Park’s own published documents

Q1 Is this authority the AHJ for residential solar at this address? Core Jurisdiction & scope

Yes. The Town of Pembroke Park (Broward County, pop. ~6,260, entirely inside the High Velocity Hurricane Zone) is the AHJ for residential rooftop PV inside its limits. It runs an in-house Building Department - Chief Building Official Emmanuel Agbenohevi - that issues building, electrical, plumbing, mechanical, zoning and floodplain permits and performs its own inspections. It is NOT a contract community: the FY2026 Adopted Budget states 'Building is fully staffed with 6 employees and 0 opens' and 'Town is fully staffed'.

Why the confidence is not higherThree independent first-party instruments agree: the Building Department page names a Chief Building Official and states 'Each contractor must register with the Town'; the FY2026 Adopted Budget's Building Fund pages carry a full personnel stack (Compensation $476,997, payroll taxes $38,160, employee insurance $84,231, retirement $66,923) against Contractual Services of only $199,323 (20%); and the FS 553.80(7)(b) report shows 5,143 inspections conducted with 7 dedicated personnel. The caller's contract-community hypothesis is DISPROVED on the expenditure side. Deduction only for the staff directory listing no inspector or plans examiner, which suggests the trade disciplines are bought in under that Contractual Services line.

department page + adopted budget + FS 553.80(7)(b) report checked 2026-09-13 https://www.tppfl.gov/187/Building-Department

Q2 What does this authority permit itself, and what does it delegate? Core Jurisdiction & scope

Both, and more: the Town permits and inspects Building, Electrical, Plumbing, Mechanical, Zoning/Planning, Engineering and Floodplain itself. Three things sit elsewhere - (a) contractor LICENSING is Broward County (State Registration & Broward County Certificate of Competency), (b) FIRE RESCUE is contracted to the Broward Sheriff's Office (BSO Fire Station 27, 2610 SW 40th Avenue), and (c) the administrative code (FBC Chapter 1) is Broward County's, written by the Broward County Board of Rules and Appeals and adopted verbatim by Town Code Sec. 5-16.

Why the confidence is not higherSec. 5-16 'The Florida Building Code, with applicable Broward County amendments, is hereby adopted and shall be the building code of the Town'; Sec. 5-125 does the same for unsafe buildings. The Building Department Document Transmittal Form has review tick-boxes for Structural, Electrical, Mechanical, Plumbing, Fire, Engineering, Public Works, Planning & Zoning and Floodplain - all routed through the Town's own desk. The Police Department page states 'For fire rescue services, the Town of Pembroke Park contracts through the Broward Sheriff's Office (BSO)'. Not 95 because the Fire tick-box on the transmittal form is not explained anywhere - whether BSO reviews residential plans is not published.

adopting ordinance + department forms checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH5BUBURE_ARTIIBUST_S5-16ADFLBUCO

Q3 Is a permit required for a residential rooftop PV system? Core Jurisdiction & scope

Yes. The Town's own Solar Panels Application Checklist opens: 'The installation, replacement or major repair of a Solar Panel (photovoltaic) requires a Permit be issued.' Separately, BORA Board Policy 22-03 (the Mandatory Countywide Rooftop Mounted Equipment Affidavit, effective 24 Oct 2022, revised 17 Nov 2022), which the Town publishes and requires with every HVHZ roofing permit, states 'PERMITS ARE REQUIRED FOR: REMOVAL AND REINSTALLATION OF PHOTOVOLTAIC PANELS.'

Why the confidence is not higherFirst-party, unambiguous, and stated twice by two different instruments. The checklist itself is dated 'Last updated: 09/2021' so it predates the FBC 8th Edition (2023) - that is a staleness caveat on its detail, not on the fact that a permit is required.

published submittal checklist checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q4 Is there a separate electrical permit, or is it combined? Core Jurisdiction & scope

Separate, and at least two of them. The Broward County Uniform Building Permit Application (Revised 01-08-2026, effective 03-09-2026) is a one-trade-per-form document ('Select One Trade: Building / Electrical / Plumbing / Mechanical / Other') and its owner's affidavit reads 'I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS'. The Solar Panels Application Checklist requires a Broward County Uniform Permit Application with Structural checked AND one with Electrical checked AND (for thermal/hybrid) one with Plumbing checked, plus a separate zoning Review Application.

Why the confidence is not higherBoth documents are first-party and current. The checklist's own wording is internally sloppy - it says the Electrical and Plumbing applications must come 'from a licensed Structural contractor', which contradicts its own CONTRACTORS paragraph lower down; read the CONTRACTORS paragraph, not the bullet.

permit application + submittal checklist checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/990/Broward-County-Uniform-Building-Permit-Application-PDF-revised-1826

Q5 Who is allowed to pull the electrical permit? Core Who may apply

Licensed electrician for the electrical permit, building/solar contractor for the building permit. The Solar Panels Application Checklist says, verbatim: 'Solar Contractors (PV) may obtain the Building permit in either Solar Thermal or Photovoltaic systems. Plumbing Contractors may obtain the master permit in the Solar Thermal category. Electrical Contractors may obtain the Electrical permit in the Photovoltaic category, being that a building contractor shall obtain the Building permit for the installation of the panels.'

Why the confidence is not higherVerbatim from the Town's own checklist - the clearest statement of the contractor split found for this authority. Not higher because the same document's bullet list says the Electrical application comes 'from a licensed Structural contractor', which is a drafting error the CONTRACTORS paragraph corrects.

published submittal checklist checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q6 Must the contractor be registered with this authority before applying? Core Who may apply

Yes, and it is a hard gate. The Building Department page states 'Each contractor must register with the Town, showing proof of their qualifications prior to obtaining a permit for construction.' The Contractors Registration Form repeats it: 'In order for contractors to obtain permit from the Town of Pembroke Park, they Must register with the building Division.' Required with the form: Qualifier's driver's licence, workers' compensation or exemption, State Registration AND Broward County Certificate of Competency, business tax receipt, State certification licence, and a general liability certificate that must name the Town of Pembroke Park as Certificate Holder.

Why the confidence is not higherTwo first-party sources, one a form. The insurance-certificate-holder requirement is the operationally expensive bit for an out-of-town installer and it is easy to miss.

department page + registration form checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/1167/Contractors-Registration-Form

Q7 Is a homeowner permitted to self-install and self-permit? Who may apply

Yes, but only at a single-family residence or a duplex. The Solar Panels Application Checklist states 'Owner/Builder applications can only be accepted for single family residences and duplex as per FS 489.103.7.a', and the same checklist requires an owner-builder to provide 'the list of labor (the cost of the standard labor must be included) and materials' in place of a signed contract. The Broward County Uniform Building Permit Application carries an Owner-Builder box and a 'License Exempted per F.S. 489.117(4)(a)1' box.

Why the confidence is not higherFirst-party and specific. Note the practical trap: most of this town's housing stock is in mobile-home parks, where the owner-builder route runs into Sec. 5-28 (the association must co-sign) and into the park's own tenancy.

published submittal checklist checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q8 What documents make up a complete submittal? Core Submittal package

A complete PV submittal here is: (1) Broward County Uniform Permit Application, Structural checked, from a licensed contractor; (2) the same application, Electrical checked; (3) a zoning Review Application; (4) survey or site plan showing the location and extension of the work; (5) association approval letter for the scope of work; (6) signed and sealed drawings by a Licensed Engineer/Architect - a roof plan to scale showing panel locations, an electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter disconnect, grounding and the AC connection to the building; specification sheets with listings of all components and installation manuals for PV modules, inverter(s), combiner box, disconnect and mounting system; attachment details, flashing details and the construction design for the unit and any supporting frame members sealed by the appropriate design professional for the Wind Zone, additional loading and site conditions; for battery backup a summary of all standby loads with power ratings and estimated daily energy consumption; and electrical calculations showing wire sizing by ampacity, conduit fill and ambient derating; (7) EITHER a Florida Solar Energy Center (FSEC) System Approval Report OR signed and sealed engineered drawings; (8) Special Inspector Form if there are connections for truss anchorage; (9) a signed contract stating the value of the scope of work; (10) a recorded Notice of Commencement if the contract price exceeds $2,500; and (11) a Building Department Document Transmittal Form, without which a submittal 'will be returned without further processing'.

Why the confidence is not higherAll of items 1-10 are verbatim from the Town's Solar Panels Application Checklist, read page by page off the rendered PDF (it is hosted on Adobe Document Cloud and has no reachable text layer). Item 11 is from the Online Permitting System page. Confidence held at 92 only because the checklist is stamped 'Last updated: 09/2021', i.e. it predates the FBC 8th Edition (2023) the Town's other forms now cite.

published submittal checklist checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q9 How many copies, and in what format? Submittal package

Electronic, by email to permits@tppfl.gov, with a Building Department Transmittal Form (BDTF) on top of every package. The Town states: 'All Submissions require a Building Department Transmittal Form (BDTF). Any Submissions missing a BDTF will be returned without further processing.' Permit revisions, shop drawings and deferred engineering submittals additionally require their own Broward County Uniform Building Application. No copy count is published.

Why the confidence is not higherFirst-party and current (the page describes a live transition off the GOV-EASY self-submission route). The copy count is genuinely not stated anywhere - the older paper-era language does not survive on the current page.

department page checked 2026-09-13 https://www.tppfl.gov/194/Online-Permitting-System

Q10 Is a site plan required, and what must it show? Core Submittal package

Yes. Two instruments require it. The Town's checklist: 'Survey or Site Plan showing the location and extension of the proposed work' plus a scaled Roof Plan 'indicating the location of the solar panels installation on the roof'. Broward's codified FBC Chapter 1, Sec. 107.3.5 building plan-review item A.14 'Photovoltaic' opens with (a) Site plan. The Broward application form itself also demands Flood Zn and BFE on its face, so the site plan has to carry flood data on any lot in a special flood hazard area.

Why the confidence is not higherThree first-party sources. The flood-data point is inferred from the application's own fields rather than stated as a site-plan content rule, which is why this is 92 not 96.

county code + submittal checklist checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q11 Is a one-line / three-line diagram required? Core Drawings & calculations

Yes - and Broward asks for a THREE-line diagram, not a one-line. Codified FBC Chapter 1 Sec. 107.3.5 electrical plan-review item B.19 'Photovoltaic' lists: (a) Layout plan including combiner box and accessible junction boxes; (b) Size of system number of modules; (c) Wire size at the coldest temperature; (d) Listing and model numbers of all equipment and racking; (e) Inverter rating and location; (f) Three-line diagram; (g) Connection to utility line side or load side Busbar ratings; (h) Grounding; (i) Labeling. The Town's own checklist requires an 'Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter disconnect, grounding, required signed and AC connection to building.'

Why the confidence is not higherRe-derived first-hand from the current codified Broward text (Municode product 15755, job 492324, 'Amendments effective through March 30, 2026'), not carried from a previous run. Held at 93 because 'three-line diagram' is a list item without a specification of what must appear on it.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q12 Are string and conductor calculations required? Drawings & calculations

Yes. The Town's checklist requires 'Electrical calculations showing that all wire sizing has been determined with proper ampacity, conduit fill and ambient derating factors.' Broward's electrical plan-review item B.19(c) independently requires 'Wire size at the coldest temperature' and B.19(g) 'Connection to utility line side or load side Busbar ratings'.

Why the confidence is not higherTwo independent first-party requirements, one municipal and one county-codified. This is one of the better-specified string/conductor requirements in the Florida survey.

submittal checklist + county code checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q13 Is a structural PE stamp required, and at what threshold? Core Engineering & stamps

Signed and sealed drawings by a Licensed Engineer or Architect are required for a PV job here - BUT the Town's checklist offers a genuine alternative: 'Choose one of the following: Florida Solar Energy Center (FSEC) System Approval Report - All solar systems drawings shall be accompanies with a FSEC Approval report --- OR --- Signed and Sealed Engineered Drawings'. County-side, Broward FBC Ch.1 107.3.4.0.3 requires a PE where work 'involves extensive computation based on structural stresses'; 107.3.4.0.6 lets the Building Official require a PE 'for any work involving structural design, regardless of the cost'; and 107.3.5.2.1 requires whole-building structural calculations for Group R3 with an Exception for 'Component systems covered by product approval or designed by a delegated professional' - which is the racking product approval. A Special Inspector Form is additionally required 'if there are connections for truss anchorage'.

Why the confidence is not higherThe FSEC alternative is a real finding and it contradicts the county-level position carried into this run: 'FSEC' returns ZERO hits across the whole 297 KB Broward FBC Chapter 1 corpus, yet the Town's own checklist names it as a substitute for sealed drawings. Held at 85 because the checklist is dated 09/2021 and FSEC's system-approval programme has changed since; a reviewer may no longer accept it. Verify before relying on it to avoid an engineer.

submittal checklist + county code checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q14 Is an electrical PE stamp required, and at what threshold? Engineering & stamps

Only above a threshold, and it is Broward's. FBC Ch.1 107.3.4.0.7: electrical plans must be prepared by a Professional Engineer for 'Residential systems requiring an aggregate electrical service capacity of more than 600 amperes or more than 240 volts' or where 'An electrical system having a cost value greater than one hundred twenty-five thousand dollars ($125,000.00)'. A normal residential PV job clears neither, so no electrical PE stamp.

Why the confidence is not higherRead first-hand from the current codified county text. Matches FS 471.003(2)(h). Note this is the CURRENT $125,000/600 A trigger, not the older $50,000 figure some Florida documents still print.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q15 What does a residential solar permit cost? Core Fees

No solar-specific fee line exists. Under the published schedule a residential PV permit is built up per discipline as: minimum permit fee $75 per discipline for work valued to $1,000, then 1.5% of value (residential, NON-cumulative) from $1,001 to $1,000,000; plus a $50 processing fee; plus a $45 flat residential plan review fee per discipline; plus an upfront inspection fee of $150 covering the first three inspections per discipline with $50 per additional inspection; plus a $35 Certificate of Completion; plus County and State surcharges; plus a 3% technology fee if paid by card. A $25,000 two-discipline (Building + Electrical) job therefore lands in the order of $900-$1,100 all-in, depending on how the Building Official apportions value between disciplines.

Why the confidence is not higherThe only fee schedule the Town publishes is 'BUILDING DEPARTMENT FY 2020-21 FEES', a Word-produced PDF created 2 Nov 2020 - six years old - while Code Sec. 5-26 says fees are set by Resolution and Sec. 5-27 says they are 'listed in the Town Commission and published in the Town's website'. No newer resolution is posted (Business Impact Statements index 2023-2026 and the Solicitations page both searched; nothing on fees). The build-up is arithmetic on a stale schedule, not a quoted number, and the per-discipline apportionment of job value is not defined anywhere - hence 62.

fee schedule (FY2020-21) checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/164/New-Fee-Schedule-FY-2020-to-2021-PDF

Q16 How is the fee calculated? Core Fees

Valuation, with flat adders. Residential: 1.5% of job value, expressly NON-cumulative (commercial is cumulative and tiered 2.0%/1.5%/1.0%); minimum $75 per discipline for work up to $1,000. Valuation is set under FBC-BCAP 109.3 and 109.3.1 - the applicant states a value, the Building Official may demand RS Means or a signed contract, and 'Final building permit valuation shall be set by the Building Official.' Flat adders: $50 processing, $45 residential plan review per discipline, $150 upfront inspection per discipline, $35 CC, 3% card technology fee.

Why the confidence is not higherDirectly quoted from the schedule. Downgraded from 90 only because the schedule is six years old.

fee schedule (FY2020-21) checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/164/New-Fee-Schedule-FY-2020-to-2021-PDF

Q17 Is there a separate plan-check fee? Fees

Yes. 'PLAN REVIEW FEES: Initial review fee charged on ALL applications (per discipline)' - residential $45 flat. Subsequent reviews: second and third review $45 flat each if comments are not cleared; 4th and subsequent disapprovals $180 (4x the first disapproval fee). Pre-plan/dry-run review $45 flat; expedited plan review $45 flat.

Why the confidence is not higherQuoted from the schedule. Note the residential expedited-review fee equals the ordinary fee, which is unusual and may mean expedited review is not actually offered residentially.

fee schedule (FY2020-21) checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/164/New-Fee-Schedule-FY-2020-to-2021-PDF

Q18 What is the stated plan-review turnaround? Core Timeline & validity

15 working days for the Building Department's written approval or denial, EXCLUDING Planning and Zoning, Engineering and Fire review. The Building Department FAQ states: 'The Code allows a period of 15 working days to provide a written answer by either approving or denying an application. This period does not include review time for Planning and Zoning, Engineering, and Fire Departments.' Broward FBC Ch.1 105.3.1.6 supplies the statutory clock behind it: a local government may not request additional information more than three times without a written waiver; where the applicant responds within 30 days the government must act within 15 days, and after a second request within 10 days.

Why the confidence is not higherFirst-party FAQ plus the codified county rule it is quoting. Held at 85 because the advertised clock could NOT be compared against real apply-to-issue dates: the Town's Gov-Easy permit register is behind a numeric CAPTCHA (see Q20) which I do not complete, so no real records were recovered.

department FAQ + county code checked 2026-09-13 https://www.tppfl.gov/187/Building-Department

Q19 How long is an issued permit valid before it expires? Timeline & validity

180 days to commence, then 90 days of abandonment kills it. Town Code Sec. 5-18 defers entirely to the FBC: 'The expiration of all issued permits shall be subject to the requirements set forth in Section 105.3.2 of the Florida Building Code.' Broward's 105.3.2.1: a permit becomes null and void if work is not commenced within 180 days of issue, or if work is suspended or abandoned for 90 days after commencement. 105.3.2.2: the Building Official may extend for no more than two 90-day periods, not to exceed one year from the initial expiration. Separately, an unpurchased APPLICATION goes void 60 days after notification (105.3.1.1), extendable once by 60 days on a written request made before expiry.

Why the confidence is not higherLocal ordinance pointing at the codified county text, both read first-hand. The 60-day application clock is the one that catches installers who get plans approved and then wait for the customer to sign.

ordinance + county code checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH5BUBURE_ARTIIBUST_S5-18PEEX

Q20 Which permit portal does this authority use? Core Portal & process

Gov-Easy (apps.gov-easy.com, clientId d60f9827-2c53-44a4-9037-31e1de2b3f09) for permit/inspection lookup and payment, and Broward County ePermits OneStop (dpep.broward.org) for the county-level approvals a job may need first - Asbestos Certificate, Transportation Concurrency and Environmental Review, and Notice of Commencement. A new system is being brought in: the Town says it is 'currently updating all forms and transitioning to a New Online Permitting System'.

Why the confidence is not higherThe Gov-Easy URL and clientId are on the Town's own Online Permitting System page and the portal renders the Town's name. Gov-Easy is a vendor not previously recorded for a Broward authority in this survey. Not 96 because the transition means the front door may change.

portal landing page checked 2026-09-13 https://www.tppfl.gov/194/Online-Permitting-System

Q21 Can the whole application be completed online? Core Portal & process

No - and the Town says so in bold on its own page. 'At this time, the GOV-EASY system does NOT provide notifications to staff for any self-submissions, scheduled inspections, or payments. You must email permits@tppfl.gov to: Request the most Current Versions; Submit Applications, Forms, and Required Documents; Request Inspections; Request Link To Make Payments.' The portal still works for viewing permit status and paying fees (card only, 3% processing fee, application/process number required).

Why the confidence is not higherVerbatim from the Town's current page. This is the single most operationally important process fact for this authority: submitting through the portal will silently go nowhere.

department page checked 2026-09-13 https://www.tppfl.gov/194/Online-Permitting-System

Q22 Which utility handles interconnection here? Core Utility interconnection

Florida Power & Light Company (FPL), an investor-owned utility under FL PSC jurisdiction.

Why the confidence is not higherProved three ways and never from a territory map. (1) Code Appendix A Article II is the FPL electric franchise: Ord. No. 06-09-01 grants FPL a 30-year non-exclusive electric franchise at 5.9% of billed residential/commercial/industrial revenues, superseding the earlier Ord. 89-3-1 (itself superseding Ord. 78-3-1). (2) The Town publishes, on its own Forms & Applications page under the Mobile Home heading, a document titled 'FPL Metter Location and Height from Grade' which is a page of FPL's own Electric Service Standards (Figure IV-13a, Section IV, sheet dated 11-04-25). (3) Code Sec. 21-x on sign wiring refers work to 'Florida Power & Light Company'. Not 100 because no single document says 'FPL serves every address in the Town'.

codified franchise + Town-published utility document checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_APXAFR_ARTIIFLPOLICO

Q23 Where does the utility sit in the sequence? Core Utility interconnection

Parallel, with a hard utility gate at the end. FPL's Electric Service Standards Section XIII: 'It is highly recommended that customers obtain FPL's written interconnection approval prior to procuring any material' and 'All net metering systems require written approval and agreement from FPL.' On the AHJ side, Broward FBC Ch.1 Sec. 110.3 B.11 makes the electrical final the moment the structure is 'deemed safe for power by the Building Official', and the final electrical inspection must precede the final structural inspection. So: apply to FPL and to the Town in parallel; FPL's written agreement and the Town's electrical final both have to land before the system energises.

Why the confidence is not higherThe two halves are each first-party and current (ESS Section XIII sheet dated 10-30-25, inside the manual PDF whose ModDate is 1 Sep 2026; Broward text effective through 30 Mar 2026). 78 rather than higher because neither document states the ordering relative to the other - that is my reading of the two together, not a published sequence.

utility DG manual + county code checked 2026-09-13 https://www.fpl.com/partner/pdf/electric-service-standards.pdf

Q24 Is a HOA or architectural approval required first? Overlays & special cases

Yes, and it is codified and mandatory - one of the strongest association gates found in this survey. Town Code Sec. 5-28: 'All building permit applications for real property located on land which is subject to legally binding covenants, conditions, rules or regulations of a property association such as a homeowners association, condominium association, or co-operative association must be co-signed by the property owner and the manager or officer of the property association prior to the issuance of any building permit.' Sec. 5-29 then makes the association responsible for ensuring the permitted work is completed in compliance. The Solar Panels Application Checklist independently requires an 'Association approval letter for the scope of work performed.'

Why the confidence is not higherCodified ordinance plus the Town's own checklist. This matters enormously here because most of the housing stock sits in mobile-home parks and co-operative/condominium communities. FLAG, not asserted: Fla. Stat. 163.04(2) bars a deed restriction or association rule that prohibits solar collectors, and '163.04' returns ZERO hits across the entire 4.27 MB Town code - so the Town's counter has no instruction on the conflict and will apply Sec. 5-28 on its face.

ordinance + submittal checklist checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH5BUBURE_ARTIIIFE_DIV1GE_S5-28PRASJOBUPEAP

Q25 Is there a historic-district review? Overlays & special cases

No. There is no historic-district review in Pembroke Park. 'Certificate of appropriateness' returns ZERO hits across the whole codified corpus; there is no historic preservation board, no design review board and no architectural review board in Chapter 2 (Administration, all thirteen articles recovered) or Chapter 28 (Zoning, all nine articles and all fifteen district divisions recovered). The only 'historic' machinery in the code is the flood ordinance's historic-building variance at Sec. 10-61.

Why the confidence is not higherProved by exhaustive search of a fully recovered 4.27 MB corpus with controls passing ('electrical' 58 hits, 'building official' 129, fabricated 'zzqqx' 0). Held at 88 rather than 95 because an absence is being asserted.

code of ordinances (full-corpus search) checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances

Q26 Is a wind or windstorm certification required? Overlays & special cases

Not a 'windstorm certification' as such - Florida Product Approval, filed before installation, plus wind evidence in the drawings. Broward FBC Ch.1 107.3.5.4: 'Product approvals shall be reviewed and approved by the building designer prior to submittal... Product approval shall be filed with the Building Official for review and approval prior to installation.' The PV plan-review list requires (d) 'Wind resistance ratings of modules', (e) 'Roof live load approval', (f) 'Fire classification of buildings and modules' and (h) 'Design load path'. The Town's checklist requires 'attachment details, flashing details, construction design for the unit and any supporting frame members (sealed by the appropriate design professional) for the Wind Zone, additional loading, and any site conditions.' NO WIND SPEED IN MPH IS STATED ANYWHERE in either corpus.

Why the confidence is not higherRead first-hand from the current codified text. IMPORTANT ANTI-CARRYOVER POINT, re-proved this run rather than inherited: across the whole 297 KB Broward FBC Chapter 1 corpus, 'NOA' = 0, 'Notice of Acceptance' = 0, 'RAS-127' = 0, 'RAS-128' = 0, 'UL 1703' = 0, 'UL 2703' = 0, 'FSEC' = 0, against passing controls ('product approval' 4, 'photovoltaic' 4, 'HVHZ' 31) and a failing fabricated control. Broward runs on Florida Product Approval; do NOT carry Miami-Dade's NOA position across. The one refinement worth keeping: an integrated PV roof is roofing, and roofing IS an NOA product class, so a solar-shingle job may answer differently from a rack-mounted one.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q27 Is a Specific Use Permit or Council approval ever required? Overlays & special cases

No. A rooftop PV array needs no special exception, variance or Town Commission approval. Chapter 28 Article IV (Supplemental District Regulations, 41 docs) and Article V (Non-conforming uses) were read in full and neither lists solar; the Special Exception and Variance application checklists on the Town Planner's page are triggered by use and dimensional relief, not by equipment. A zoning Review Application IS required with every PV submittal, but that is a staff-level review, not a hearing.

Why the confidence is not higherAn absence, proved against a fully recovered zoning chapter with controls passing. Held at 72 because the zoning Review Application form itself is not published on the website - only named in the solar checklist - so I cannot see what it asks or who signs it. A ground mount could reach a different answer; see Q47.

code of ordinances (full-corpus search) checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH28ZO

Q28 Is there a system-size cap on residential generation? Overlays & special cases

No Town-level cap. The binding limits are FPL's: net metering tiers are Tier 1 up to and including 10 kW AC, Tier 2 over 10 kW to 100 kW, Tier 3 over 100 kW to 2 MW; and 'Customer generation is limited to 90 percent of the FPL distribution service rating (Transformer).' Crossing 10 kW AC moves a residential job from Tier 1 into Tier 2 and triggers the mandatory visually-open DER disconnect switch (see Q48), so 10 kW AC is the number that changes the job.

Why the confidence is not higherFPL's tiers and the 90% limit read first-hand off the current Section XIII (sheet dated 10-30-25). The Town-level absence is proved against the full code corpus. 80 rather than 90 because the 90% transformer limit is a design constraint FPL applies case by case, not a published number the installer can check in advance.

utility DG manual + code absence checked 2026-09-13 https://www.fpl.com/partner/pdf/electric-service-standards.pdf

Lines marked with a percentage were read off this authority’s own published documents. Unmarked guidance is general good practice, not this jurisdiction’s rule — always confirm against the authority before you submit.

Install 5 steps · 20 questions
  1. Build to the code editions actually in force here

    The NEC edition a jurisdiction enforces is often a cycle behind the newest one published, and local amendments sit on top of it. Rapid shutdown, conductor sizing and labelling all change between editions, so the edition in force is the first thing to establish, not the last.

    • Which NEC edition is in force? NEC 2020 (NFPA 70-2020), in force through the Florida Building Code 8th Edition (2023), effective 31 December 2023. 90% · state code adoption via county/local floating adoption
    • Which building code edition is in force? Florida Building Code 8th Edition (2023), with the Broward County amendments, adopted as the Town's building code by Code Sec. 5-16 on a floating basis ('as amended from time to time'). The Broward amendment set currently codified is 'THE FLORIDA BUILDING CODE / BROWARD COUNTY AMENDMENTS ... Codified through Amendments effective through March 30, 2026 (Supp. No. 1, Update 6)'. The whole Town is inside the High Velocity Hurricane Zone. 94% · adopting ordinance + county code banner
    • Which fire code edition is in force? In practice: Florida Fire Prevention Code 8th Edition (2023) with the Broward County amendments (Municode product 15779, 'Amendments adopted through July 10, 2025, effective July 21, 2025'). But the TOWN'S OWN codified fire chapter is a 33-year-old fossil: Code Sec. 9-16 still adopts 'The South Florida Building Code, 1992, Broward County Edition, the National Fire Protection Association Life Safety Code 101 ... as the Pembroke Park Fire Code', and Sec. 9-23 resolves conflicts against 'the South Florida Building Code, as adopted by the Town' - a code that ceased to exist in 2002. Fire rescue itself is contracted to the Broward Sheriff's Office. 80% · codified ordinance + county fire code amendments
    • Are there local amendments to any of the above? Yes - but they are the COUNTY'S, not the Town's. Broward County, through its Board of Rules and Appeals, publishes a full codified replacement for FBC Chapter 1 (administration) and the Town adopts it verbatim. The Town itself has NO technical amendments: Chapter 5 Article II is three operative sections (5-16 adoption, 5-17 permit process, 5-18 expiration) and adds only procedure - a notarised application per FS 713.135(5), simultaneous multi-discipline submittal per FBC 107, and qualification of applicants under FBC 105.3.0.1.1. 92% · county code + local adopting ordinance
    • What is the installation judged against? FBC 8th Edition (2023) as amended by Broward County, NEC 2020 via FBC Chapter 27, and HVHZ provisions throughout - plus Florida Product Approval filed with the Building Official before installation. Broward FBC Ch.1 101.4.1: 'The provisions of Chapter 27 of the FBC, Building, NFPA 70, Fire Protection Provisions of this Code, and the FFPC shall apply to electrical components, equipment, and systems.' 90% · county code (FBC Ch.1 amendments)
  2. Fire access, setbacks and pathways

    Ridge setbacks and roof access pathways are fire-service requirements and they constrain the array layout. They are the most common cause of a redesign after the fire department comments on a plan set.

    Nothing recorded for Town of Pembroke Park on this step yet — 1 question checked and found unpublished. The guidance above is general.

  3. Rapid shutdown

    Which rapid-shutdown rule applies follows directly from the NEC edition in force, and the initiation device has to be at a location the fire service can reach and identify. This is inspected, and it is labelled.

    • Is rapid shutdown required, and to which NEC edition? Yes - NEC 2020 Article 690.12 module-level rapid shutdown applies, by state code adoption. No authority in this chain restates or amends it. Broward's FBC Chapter 1 corpus contains ZERO occurrences of 'rapid shutdown'; a Town-wide site search for 'rapid shutdown' returns nine results, none of which is about PV (they are Broward County assistance programmes and a police job description). 80% · state code by adoption; local absence proved
  4. Labels and placards

    The NEC sets a baseline for permanent markings at the service equipment and the disconnecting means. On top of that, an authority may specify its own wording, and the utility may specify more again. Where any of them writes its own text, a generic off-the-shelf label set will not pass — this is the detail most often fixed on a return visit.

    • Which placards does this authority require at the service equipment? Neither the Town nor Broward County specifies any placard by wording. Broward's electrical plan-review item B.19(i) is the bare word 'Labeling', and the electrical final requires the inspector to 'Verify proper labeling' - both point at NEC 2020 Article 690/705 without restating it. The placards that ARE specified by wording at this address come from FPL (see Q42). 78% · county code + local corpus (absence proved)
    • Does the authority specify placard wording of its own? No. The Town specifies no placard wording of its own. 'Solar' appears exactly ONCE in the Town's entire 4.27 MB codified corpus and the hit is 'solariums' in a Chapter 15 list of businesses whose employees need identification cards - a new contamination flavour for this survey, alongside 'Solar Flare' and solar reflective index. 'Photovoltaic' appears ZERO times. 85% · code of ordinances (full-corpus search)
    • Does it specify letter height, colour or material? The Town and county specify nothing. FPL does, and it is unusually specific: 'All labels must be permanent and weatherproof/UV resistant placard with engraved letters. The customer is responsible for all labeling requirements.' Engraved, not printed - that rules out an adhesive label for the two FPL placards. 85% · utility DG manual
    • Does the UTILITY specify placards beyond the AHJ's? Yes. FPL Electric Service Standards Section XIII item 6 specifies two placards by exact text, and the battery policy specifies a third: AT THE INTERCONNECTING METER CAN - 'WARNING / MULTI POWER SOURCES / ENTER SOURCES HERE / RATED AC OUTPUT CURRENT ** AMPS / NOMINAL OPERATING VOLTAGE ** VOLTS'. AT THE DER DISCONNECT SWITCH - 'GENERATION SYSTEM AC DISCONNECT / RATED AC OUTPUT CURRENT ** AMPS / NOMINAL OPERATING VOLTAGE ** VOLTS'. AND FOR BATTERY STORAGE - 'A placard must be permanently affixed to the meter enclosure stating "Battery storage utilized in this facility."' 92% · utility DG manual
    • Where must the labels be placed? At the interconnecting meter can and at the DER disconnect switch (FPL's two placards), and permanently affixed to the meter enclosure for the battery placard. FPL: 'The following labels must be installed at the interconnecting meter can and the DER disconnect switch.' No AHJ-side placement rule exists at Town or county level. 90% · utility DG manual
  5. Disconnect, storage and listed equipment

    Where the AC disconnect must sit relative to the meter is usually the utility's rule, not the building department's. Battery storage frequently carries its own permit, its own inspection and its own fire conditions.

    • Where must the AC disconnect be, relative to the meter? It depends on tier AND on tap point, and both come from FPL. (1) TIER 2 AND TIER 3 (over 10 kW AC): 'All tier 2 and tier 3 systems require an FPL approved visually open Distributed Energy Resource (DER) disconnect switch... The manual disconnect switch must be mounted separate from but adjacent to the FPL meter socket within 10 feet and must always remain accessible to FPL. Plans must show dimensions between the location of the meter socket and the DER disconnect switch. There shall be no locked gates, doors or fences between the meter socket and the DER disconnect switch.' It must be visible-open (blades, jaws and air gap visible), not obscured by a dead-front or arc-shield, lockable in the open position, take an FPL 3/8-inch padlock shank on the cover hasp, be unmodified, properly grounded, and connected so the blades are de-energised when open per NEC 404.6(C). (2) TIER 1 (10 kW AC or less), LOAD SIDE: no disconnect - 'FPL recommends that all interconnections will be performed on the load side of the customer's main electrical panel.' (3) TIER 1, LINE SIDE: 'If the interconnection is performed on the line side of the customers main electrical panel (per NEC) a manual AC disconnect is required between AC generation output and the point of interconnection to FPL facilities. The manual disconnect switch must be mounted separate from but adjacent to the FPL meter socket within 10 feet.' Line-side taps are CONDITIONED, not prohibited. 93% · utility DG manual
    • Must equipment be on a specific approved list? Yes - Florida Product Approval, and it must be ON FILE WITH THE BUILDING OFFICIAL BEFORE INSTALLATION, not merely referenced. Broward FBC Ch.1 107.3.5.4: 'Product approvals shall be reviewed and approved by the building designer prior to submittal to verify that such products comply with the design specifications. Reviewed and approved product approvals shall become part of the plans or specifications. Product approval shall be filed with the Building Official for review and approval prior to installation.' The electrical plan-review list separately requires (d) 'Listing and model numbers of all equipment and racking'. The Town's checklist requires 'Specification sheets with listings of all components, installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnect, and mounting system.' 90% · county code (FBC Ch.1 amendments)
    • Are batteries permitted, and under what conditions? Yes, batteries are permitted, and the requirements are split between the submittal and the utility. Town side: the Solar Panels Application Checklist requires, for battery backup systems, 'a summary of all standby loads, including power ratings and estimated daily energy consumption for each load to show that inverter and battery selection will meet the standby needs.' FPL side: battery storage behind the meter must be NRTL-certified to UL 1741 (non-certified batteries must be DC-coupled behind a UL 1741 listed device); a placard must be permanently affixed to the meter enclosure; energy stored is for the customer's own use and MAY NOT be exported to the grid; a battery installed without renewable generation and charged from the grid needs no interconnection agreement but the customer must prevent back-feed; a battery designed to charge from the grid and operate interconnected must be notified to FPL via a Small Generator Interconnection Application. Stand-alone storage is not 'renewable energy' under Rule 25-6.065(2)(d) and is not net metered. 80% · submittal checklist + utility DG manual
    • Is a ground mount treated as a structure? Yes, and the consequence is a hard setback bar. The zoning definition is broad: 'Structure means anything constructed or erected, the use of which requires more or less permanent location on the land, or attached to something having a permanent location on the land. "Structure" includes the word "building".' The Setback definition then closes the door: 'In all setback areas as provided for in this Code, in all open space, there shall be no permanent improvements of any type, including but not limited to parking spaces, driveways, sidewalks, buildings, or structures of any type. This shall not prohibit any landscaping, trellises, and fences in the setback.' The exception list is closed and does not reach PV equipment, inverters or battery pads. In the T-1 Mobile Home Park District, Sec. 28-266(4) adds 'No accessory building or structure shall be placed in any required yard space', and Sec. 28-267 sets separations of 3 ft for a noncombustible and 5 ft for a combustible accessory structure from an adjacent unit or a park service building. 88% · code of ordinances (zoning)
    • Is there a local rule on service upgrades or busbar sizing? No numeric local rule, but busbar sizing is a NAMED plan-review item, which means a reviewer will look for it. Broward FBC Ch.1 Sec. 107.3.5 electrical item B.19(g): 'Connection to utility line side or load side Busbar ratings'. A service change, where the design needs one, is a distinct inspection in its own right - Sec. 110.3 electrical PV item 10(c) 'Service change, if required by the design'. Separately the Town runs a stand-alone 'Electrical Service - Change Application Checklist'. 85% · county code (FBC Ch.1 amendments)
    • Is a specific mounting system or attachment spacing required? No prescriptive attachment spacing, but a heavily specified attachment package. Broward FBC Ch.1 Sec. 107.3.5 building item A.14 'Photovoltaic' requires: (a) Site plan; (b) Roof penetration approval; (c) Roof sealing detail; (d) Wind resistance ratings of modules; (e) Roof live load approval; (f) Fire classification of buildings and modules; (g) Rooftop shingle module ratings, if installed; (h) Design load path. The Town adds: 'Provide the attachment details, flashing details, construction design for the unit and any supporting frame members (sealed by the appropriate design professional) for the Wind Zone, additional loading, and any site conditions', and requires a Special Inspector Form where there are connections for truss anchorage. At the rough inspection the inspector checks 'attachments, penetrations on the roof, torque requirements'. 88% · county code + submittal checklist

20 questions answered against Town of Pembroke Park’s own published documents

Q29 Which NEC edition is in force? Core Code editions in force

NEC 2020 (NFPA 70-2020), in force through the Florida Building Code 8th Edition (2023), effective 31 December 2023.

Why the confidence is not higherThe statewide answer; nothing local displaces it. Broward's FBC Ch.1 101.4.1 refers to 'NFPA 70' without a year, and the Town's code adopts the FBC 'as amended from time to time', so the year is not a local fact. WATCH THE 2023 TRAP: the Town's own forms print 'FBC 8th Edition (2023)' and its User Fees page still says 'On December 31, 2020, the FBC 2020 7th Edition went into effect' - neither number is the NEC edition.

state code adoption via county/local floating adoption checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q30 Which building code edition is in force? Core Code editions in force

Florida Building Code 8th Edition (2023), with the Broward County amendments, adopted as the Town's building code by Code Sec. 5-16 on a floating basis ('as amended from time to time'). The Broward amendment set currently codified is 'THE FLORIDA BUILDING CODE / BROWARD COUNTY AMENDMENTS ... Codified through Amendments effective through March 30, 2026 (Supp. No. 1, Update 6)'. The whole Town is inside the High Velocity Hurricane Zone.

Why the confidence is not higherOrdinance plus the county product's own banner text, both read this run. The Town's forms corroborate ('FBC 8th Edition (2023) HVHZ Uniform Roofing Application', 'FBC Special Building Inspector Form 8th Edition').

adopting ordinance + county code banner checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH5BUBURE_ARTIIBUST_S5-16ADFLBUCO

Q31 Which fire code edition is in force? Code editions in force

In practice: Florida Fire Prevention Code 8th Edition (2023) with the Broward County amendments (Municode product 15779, 'Amendments adopted through July 10, 2025, effective July 21, 2025'). But the TOWN'S OWN codified fire chapter is a 33-year-old fossil: Code Sec. 9-16 still adopts 'The South Florida Building Code, 1992, Broward County Edition, the National Fire Protection Association Life Safety Code 101 ... as the Pembroke Park Fire Code', and Sec. 9-23 resolves conflicts against 'the South Florida Building Code, as adopted by the Town' - a code that ceased to exist in 2002. Fire rescue itself is contracted to the Broward Sheriff's Office.

Why the confidence is not higherBoth instruments read first-hand. The gap between them is the finding. Held at 80 because nothing published says which document a Pembroke Park plan reviewer actually applies; state adoption of the FFPC makes the 1992 SFBC unenforceable, but the codified text has never been repealed.

codified ordinance + county fire code amendments checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH9FIPRPR

Q32 Are there local amendments to any of the above? Core Code editions in force

Yes - but they are the COUNTY'S, not the Town's. Broward County, through its Board of Rules and Appeals, publishes a full codified replacement for FBC Chapter 1 (administration) and the Town adopts it verbatim. The Town itself has NO technical amendments: Chapter 5 Article II is three operative sections (5-16 adoption, 5-17 permit process, 5-18 expiration) and adds only procedure - a notarised application per FS 713.135(5), simultaneous multi-discipline submittal per FBC 107, and qualification of applicants under FBC 105.3.0.1.1.

Why the confidence is not higherBoth corpora read in full this run. The Broward amendments are the substantive local law for a PV job here and they are the reason this authority answers Q11/Q12/Q34/Q35/Q44/Q54/Q55/Q56/Q57 at all.

county code + local adopting ordinance checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q33 What is the installation judged against? Core Electrical

FBC 8th Edition (2023) as amended by Broward County, NEC 2020 via FBC Chapter 27, and HVHZ provisions throughout - plus Florida Product Approval filed with the Building Official before installation. Broward FBC Ch.1 101.4.1: 'The provisions of Chapter 27 of the FBC, Building, NFPA 70, Fire Protection Provisions of this Code, and the FFPC shall apply to electrical components, equipment, and systems.'

Why the confidence is not higherRead first-hand. Straightforward once Q29/Q30/Q32 are settled.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q34 Is there a local rule on service upgrades or busbar sizing? Electrical

No numeric local rule, but busbar sizing is a NAMED plan-review item, which means a reviewer will look for it. Broward FBC Ch.1 Sec. 107.3.5 electrical item B.19(g): 'Connection to utility line side or load side Busbar ratings'. A service change, where the design needs one, is a distinct inspection in its own right - Sec. 110.3 electrical PV item 10(c) 'Service change, if required by the design'. Separately the Town runs a stand-alone 'Electrical Service - Change Application Checklist'.

Why the confidence is not higherThe plan-review item and the inspection item are both read first-hand from the current codified text. No 120%-rule restatement or local busbar table exists; NEC 705.12 applies by default.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q35 Is a specific mounting system or attachment spacing required? Structural & mounting

No prescriptive attachment spacing, but a heavily specified attachment package. Broward FBC Ch.1 Sec. 107.3.5 building item A.14 'Photovoltaic' requires: (a) Site plan; (b) Roof penetration approval; (c) Roof sealing detail; (d) Wind resistance ratings of modules; (e) Roof live load approval; (f) Fire classification of buildings and modules; (g) Rooftop shingle module ratings, if installed; (h) Design load path. The Town adds: 'Provide the attachment details, flashing details, construction design for the unit and any supporting frame members (sealed by the appropriate design professional) for the Wind Zone, additional loading, and any site conditions', and requires a Special Inspector Form where there are connections for truss anchorage. At the rough inspection the inspector checks 'attachments, penetrations on the roof, torque requirements'.

Why the confidence is not higherThree first-party layers, all read this run. Item (g) is the one to notice: 'Rooftop shingle module ratings, if installed' is Broward contemplating integrated PV roofing, which is a roofing product class and therefore an NOA class - a solar shingle job may answer Q26/Q44 differently from a rack-mounted one.

county code + submittal checklist checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q36 What ridge setback and access pathways are required? Core Fire pathways & setbacks

Nothing published by this authority.

Where we lookedFire access pathways and ridge setbacks for rooftop PV. Searched: Broward County's codified amendments to the Florida Fire Prevention Code in full (Municode clientId 12263, product 15779, job 479701, 'Amendments adopted through July 10, 2025, effective July 21, 2025'; 105 KB, 23 documents, 8,187 chars/doc so no lockout) - 'photovoltaic' 0, 'solar' 0, 'pathway' 0, 'ridge' 0, 'setback' 0, '1204' 0, against a passing control ('fire' 567) and a failing fabricated control ('zzqqx' 0). Also searched Broward's FBC Chapter 1 amendments in full (297 KB) where the only fire words attached to PV are 'Fire classification of buildings and modules' in the plan-review list; the Town's codified Chapter 9 Fire Prevention and Protection, which is a 1992 South Florida Building Code fossil with nothing on PV; the Town's Solar Panels Application Checklist; and a Town-wide site search for 'rapid shutdown' and 'solar'. NOTHING in this chain restates or amends the FFPC access-pathway provisions, and fire rescue is contracted out to the Broward Sheriff's Office whose residential plan-review role is not published. No local answer is recordable.

https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_fire_prevention_code

Q37 Is rapid shutdown required, and to which NEC edition? Core Rapid shutdown

Yes - NEC 2020 Article 690.12 module-level rapid shutdown applies, by state code adoption. No authority in this chain restates or amends it. Broward's FBC Chapter 1 corpus contains ZERO occurrences of 'rapid shutdown'; a Town-wide site search for 'rapid shutdown' returns nine results, none of which is about PV (they are Broward County assistance programmes and a police job description).

Why the confidence is not higherThe requirement is real and statewide; the local answer is an absence and it is proved with a passing control (site search 'roofing' 44 results, 'solar' 11, fabricated 'zzqqxyz' 0). 80 rather than 90 because the Town's Solar Panels Application Checklist - the one document that would tell an installer - is dated 09/2021 and says nothing about rapid shutdown at all.

state code by adoption; local absence proved checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q38 Which placards does this authority require at the service equipment? Core Labels Signage & labelling

Neither the Town nor Broward County specifies any placard by wording. Broward's electrical plan-review item B.19(i) is the bare word 'Labeling', and the electrical final requires the inspector to 'Verify proper labeling' - both point at NEC 2020 Article 690/705 without restating it. The placards that ARE specified by wording at this address come from FPL (see Q42).

Why the confidence is not higherA proved absence at AHJ level against a fully read county corpus and a fully recovered 4.27 MB town corpus, plus the Town's own solar checklist which requires 'Labeling' on the electrical diagram but specifies no text. The practical answer for an installer is therefore: NEC-required labels plus FPL's two placards plus, if there is a battery, FPL's meter-enclosure placard.

county code + local corpus (absence proved) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q39 Does the authority specify placard wording of its own? Core Labels Signage & labelling

No. The Town specifies no placard wording of its own. 'Solar' appears exactly ONCE in the Town's entire 4.27 MB codified corpus and the hit is 'solariums' in a Chapter 15 list of businesses whose employees need identification cards - a new contamination flavour for this survey, alongside 'Solar Flare' and solar reflective index. 'Photovoltaic' appears ZERO times.

Why the confidence is not higherProved against a corpus that was fully recovered after the Municode empty-chapter lockout fired on five chapters including Buildings, Flood and Zoning (see the method note). Controls passing: 'electrical' 58, 'mobile home' 213, 'building official' 129, fabricated 'zzqqx' 0.

code of ordinances (full-corpus search) checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances

Q40 Does it specify letter height, colour or material? Core Labels Signage & labelling

The Town and county specify nothing. FPL does, and it is unusually specific: 'All labels must be permanent and weatherproof/UV resistant placard with engraved letters. The customer is responsible for all labeling requirements.' Engraved, not printed - that rules out an adhesive label for the two FPL placards.

Why the confidence is not higherVerbatim from FPL Electric Service Standards Section XIII item 6, sheet dated 10-30-25, read by OCR of the rendered pages. No colour or letter-height dimension is given. 85 not 95 because this is the utility's rule, not the AHJ's, and the AHJ will not enforce it.

utility DG manual checked 2026-09-13 https://www.fpl.com/partner/pdf/electric-service-standards.pdf

Q41 Is a site plan / facility map placard required, and what must it show? Core Labels Signage & labelling

Nothing published by this authority.

Where we lookedWhether a site-plan / facility-map placard is required (NEC 705.10 style). Searched: the Town's full codified corpus - Charter, Code of Ordinances and all appendices via the Municode content API (clientId 9360, product 10292, job 490992, 'Codified through Ordinance No. 2026-008, adopted February 16, 2026, Supp. No. 43'), 1,815 documents and 4.27 MB after recovering five lockout chapters - 'solar' 1 hit and it is 'solariums', 'photovoltaic' 0, so nothing on placards at all; Broward's FBC Chapter 1 amendments in full, where '705.' returns 0 and the only PV labelling references are the bare word 'Labeling' in the plan-review list and 'Verify proper labeling' at the electrical final; the Town's Solar Panels Application Checklist, which requires an electrical diagram but names no placard; and FPL's Electric Service Standards Section XIII, which specifies two placards by exact wording and a battery placard but no facility map. NEC 2020 705.10 applies by default through the state code adoption, but NO authority here restates or amends it. This is now the FIFTH consecutive Florida run in which nobody restates 705.10.

https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q42 Does the UTILITY specify placards beyond the AHJ's? Core Labels Signage & labelling

Yes. FPL Electric Service Standards Section XIII item 6 specifies two placards by exact text, and the battery policy specifies a third: AT THE INTERCONNECTING METER CAN - 'WARNING / MULTI POWER SOURCES / ENTER SOURCES HERE / RATED AC OUTPUT CURRENT ** AMPS / NOMINAL OPERATING VOLTAGE ** VOLTS'. AT THE DER DISCONNECT SWITCH - 'GENERATION SYSTEM AC DISCONNECT / RATED AC OUTPUT CURRENT ** AMPS / NOMINAL OPERATING VOLTAGE ** VOLTS'. AND FOR BATTERY STORAGE - 'A placard must be permanently affixed to the meter enclosure stating "Battery storage utilized in this facility."'

Why the confidence is not higherAll three read first-hand this run by rendering and OCRing Section XIII (pages 161-173 of the manual). NOTE THE RETRIEVAL TRAP, still live: pdftotext returns Section XIII as mojibake while the other ~160 pages extract cleanly, so OCR just those pages. The manual's PDF ModDate is 1 Sep 2026 and the Section XIII sheets are dated 10-30-25.

utility DG manual checked 2026-09-13 https://www.fpl.com/partner/pdf/electric-service-standards.pdf

Q43 Where must the labels be placed? Core Labels Signage & labelling

At the interconnecting meter can and at the DER disconnect switch (FPL's two placards), and permanently affixed to the meter enclosure for the battery placard. FPL: 'The following labels must be installed at the interconnecting meter can and the DER disconnect switch.' No AHJ-side placement rule exists at Town or county level.

Why the confidence is not higherVerbatim from the current Section XIII. The AHJ-side absence is proved against both corpora.

utility DG manual checked 2026-09-13 https://www.fpl.com/partner/pdf/electric-service-standards.pdf

Q44 Must equipment be on a specific approved list? Equipment listing

Yes - Florida Product Approval, and it must be ON FILE WITH THE BUILDING OFFICIAL BEFORE INSTALLATION, not merely referenced. Broward FBC Ch.1 107.3.5.4: 'Product approvals shall be reviewed and approved by the building designer prior to submittal to verify that such products comply with the design specifications. Reviewed and approved product approvals shall become part of the plans or specifications. Product approval shall be filed with the Building Official for review and approval prior to installation.' The electrical plan-review list separately requires (d) 'Listing and model numbers of all equipment and racking'. The Town's checklist requires 'Specification sheets with listings of all components, installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnect, and mounting system.'

Why the confidence is not higherThree first-party layers. This is Florida Product Approval, NOT a Miami-Dade NOA - re-proved this run with zero-hit searches for NOA / Notice of Acceptance / RAS-127 / RAS-128 / UL 1703 / UL 2703 against passing controls. The single refinement: integrated PV roofing is roofing, and roofing is an NOA product class.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q45 Are batteries permitted, and under what conditions? Core Battery / ESS

Yes, batteries are permitted, and the requirements are split between the submittal and the utility. Town side: the Solar Panels Application Checklist requires, for battery backup systems, 'a summary of all standby loads, including power ratings and estimated daily energy consumption for each load to show that inverter and battery selection will meet the standby needs.' FPL side: battery storage behind the meter must be NRTL-certified to UL 1741 (non-certified batteries must be DC-coupled behind a UL 1741 listed device); a placard must be permanently affixed to the meter enclosure; energy stored is for the customer's own use and MAY NOT be exported to the grid; a battery installed without renewable generation and charged from the grid needs no interconnection agreement but the customer must prevent back-feed; a battery designed to charge from the grid and operate interconnected must be notified to FPL via a Small Generator Interconnection Application. Stand-alone storage is not 'renewable energy' under Rule 25-6.065(2)(d) and is not net metered.

Why the confidence is not higherTown side verbatim from the checklist; FPL side verbatim from Section XIII part C, OCRed this run. 80 not 90 because there is NO local fire-code provision on energy storage at all: 'energy storage' returns zero genuine hits across Broward's FFPC amendments (controls: 'fire' 567, fabricated 'zzqqx' 0) and the Town's fire chapter is a 1992 fossil.

submittal checklist + utility DG manual checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q46 Is there a separate ESS permit or inspection? Battery / ESS

Nothing published by this authority.

Where we lookedWhether a separate ESS permit or inspection exists. Searched: the Town's full codified corpus (no 'energy storage', no 'battery' in any building or fire context); Broward's FBC Chapter 1 amendments, whose Sec. 110.3 inspection list runs to 22 building items and 11 electrical items with no ESS entry and whose Sec. 107.3.5 plan-review lists have no ESS entry; Broward's FFPC amendments (zero genuine 'energy storage' hits against passing controls); the Town's Submittal Checklists page, which publishes eleven checklists - Air Conditioning Changeout, Cooling Towers, Demolition, Electrical Service Change, Fence, Generator, Kitchen/Bath, Residential Driveway, Roofing, Solar Panels, Windows and Doors - and none of them is a battery or ESS checklist; and the Solar Panels Application Checklist itself, which treats battery backup as a drawing requirement inside the PV submittal rather than as a separate permit. The Gov-Easy portal's permit-type catalogue could not be enumerated (see Q20 note on the CAPTCHA), so a portal-side check was not possible.

https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q47 Is a ground mount treated as a structure? Core Ground mount

Yes, and the consequence is a hard setback bar. The zoning definition is broad: 'Structure means anything constructed or erected, the use of which requires more or less permanent location on the land, or attached to something having a permanent location on the land. "Structure" includes the word "building".' The Setback definition then closes the door: 'In all setback areas as provided for in this Code, in all open space, there shall be no permanent improvements of any type, including but not limited to parking spaces, driveways, sidewalks, buildings, or structures of any type. This shall not prohibit any landscaping, trellises, and fences in the setback.' The exception list is closed and does not reach PV equipment, inverters or battery pads. In the T-1 Mobile Home Park District, Sec. 28-266(4) adds 'No accessory building or structure shall be placed in any required yard space', and Sec. 28-267 sets separations of 3 ft for a noncombustible and 5 ft for a combustible accessory structure from an adjacent unit or a park service building.

Why the confidence is not higherAll four provisions read first-hand from the recovered Chapter 28. The setback clause is the operative one for any ground mount, inverter pad or battery enclosure and it is unusually absolute. Held at 88 because no document applies it to PV explicitly - this is the definition applied to the facts.

code of ordinances (zoning) checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH28ZO

Q48 Where must the AC disconnect be, relative to the meter? Core Utility equipment

It depends on tier AND on tap point, and both come from FPL. (1) TIER 2 AND TIER 3 (over 10 kW AC): 'All tier 2 and tier 3 systems require an FPL approved visually open Distributed Energy Resource (DER) disconnect switch... The manual disconnect switch must be mounted separate from but adjacent to the FPL meter socket within 10 feet and must always remain accessible to FPL. Plans must show dimensions between the location of the meter socket and the DER disconnect switch. There shall be no locked gates, doors or fences between the meter socket and the DER disconnect switch.' It must be visible-open (blades, jaws and air gap visible), not obscured by a dead-front or arc-shield, lockable in the open position, take an FPL 3/8-inch padlock shank on the cover hasp, be unmodified, properly grounded, and connected so the blades are de-energised when open per NEC 404.6(C). (2) TIER 1 (10 kW AC or less), LOAD SIDE: no disconnect - 'FPL recommends that all interconnections will be performed on the load side of the customer's main electrical panel.' (3) TIER 1, LINE SIDE: 'If the interconnection is performed on the line side of the customers main electrical panel (per NEC) a manual AC disconnect is required between AC generation output and the point of interconnection to FPL facilities. The manual disconnect switch must be mounted separate from but adjacent to the FPL meter socket within 10 feet.' Line-side taps are CONDITIONED, not prohibited.

Why the confidence is not higherRead first-hand this run by OCRing Section XIII of the current manual (sheets dated 10-30-25). This re-confirms the corrected baseline position and specifically confirms that the older 'Section XIII prohibits line-side taps' reading is wrong for the current text. Not 96 only because FPL's own DER-disconnect requirements page phrases the scope as 'all DER installations ranging from 10kW to 2MW', which is the same thing said differently.

utility DG manual checked 2026-09-13 https://www.fpl.com/partner/pdf/electric-service-standards.pdf

Lines marked with a percentage were read off this authority’s own published documents. Unmarked guidance is general good practice, not this jurisdiction’s rule — always confirm against the authority before you submit.

Inspection 5 steps · 14 questions
  1. Book it

    Booking is a portal, a phone call or an email depending on the authority, and the notice required is rarely zero. Book before the work is finished rather than after — the lead time, not the work, is usually what sets the date.

    • How is an inspection booked? Email, or phone. The Town instructs 'You must email permits@tppfl.gov to... Request Inspections'. The Building Department page publishes 'Open to Calls for Inspection 8 am to 4 pm' on 954-966-4600. Gov-Easy has a Request Inspection module but the Town warns it does not notify staff, so it is not a working route. 88% · department page
    • Are same-day or AM/PM windows offered? No same-day service and no AM/PM window is published. What IS published is the opposite end: 'OVERTIME INSPECTIONS: After hours and/or weekend (per discipline) $250.00 for the first 3 hours; additional hours at $75.00/hr', and a call window of 8 am to 4 pm for booking. 60% · fee schedule + department page
  2. Know who turns up

    Some authorities inspect their own solar work; some delegate it, and a few do not inspect the PV equipment itself at all. Who is coming determines what they will look at.

    • Does this AHJ perform its own final solar inspection? Yes. The Town performs its own inspections. Its FS 553.80(7)(b) Building Permit & Inspection Utilization Report for FY2024-2025 records 5,143 building inspections and re-inspections requested and 5,143 conducted, of which exactly ONE was conducted by a private provider, with 4 audits of private-provider work, and 7 personnel dedicated to enforcing the Florida Building Code. 92% · FS 553.80(7)(b) report
    • If delegated, to whom? Not delegated. The optional alternative is FS 553.791 private provider, which is fully operational here: the Town publishes a Private Providers page with a Registration Application Index, Registration and Application Procedures, Forms A-E and Forms R.1-R.3 (including a Private Provider Agreement), and the Broward County Uniform Building Permit Application asks on its face 'Private Provider? YES/NO - If yes, attach Form # 61G20-2.005-2002-01' and 'Per F.S. 553.791(2)(a), do you have the written fee owner's authorization to use a private provider?' 88% · department page + permit application
  3. Work the stages in order

    A rough-in or mid-roof inspection, where one is required, has to happen before the work it covers is closed up. Missing a stage means opening something back up, and it is the most expensive kind of correction.

    • Which inspections are required, and in what order? Two disciplines, four inspections, in a fixed order, and Broward codifies it. BUILDING (Sec. 110.3 item 20 'Photovoltaic'): (a) Rough - 1. Check specifications, model numbers, and layout; 2. Check attachments, penetrations on the roof, torque requirements; (b) Final. ELECTRICAL (Sec. 110.3 item 10 'Photovoltaic'): (a) Rough, BEFORE MODULES ARE INSTALLED - 1. Check specifications, model numbers, and layout; 2. All wiring for junction boxes, combiner, and inverter completed; 3. Grounding system completed, torque requirements. EXCEPTION: 'The modules for rail-less systems may not require a rough inspection.' (b) Final - the module must be available for inspection - 1. Verify proper labeling; 2. Test system. (c) Service change, if required by the design. THE ORDER RULE: 'The final electrical inspection shall be made prior to the final structural inspection.' 94% · county code (FBC Ch.1 amendments)
    • Is a rough-in or mid-roof inspection required? Yes, and the electrical rough is scheduled unusually early: 'Rough. Before modules are installed'. The building rough is separate and checks attachments, roof penetrations and torque. The only relief is the rail-less exception: 'The modules for rail-less systems may not require a rough inspection' - note 'may not', which leaves it to the inspector rather than exempting the system. 94% · county code (FBC Ch.1 amendments)
  4. Have the paperwork on site

    The approved plan set, the permit, and the equipment listings should be on site and reachable. Inspectors routinely verify that installed equipment matches what was approved, and that the labels are the ones the plan set promised.

    • Is there a published inspection checklist? Yes - two of them, at two levels. County: Broward's codified FBC Chapter 1 is itself the checklist, with a dedicated photovoltaic plan-review list (Sec. 107.3.5 structural item A.14 and electrical item B.19) and a dedicated photovoltaic inspection sequence (Sec. 110.3 building item 20 and electrical item 10). Town: the Solar Panels Application Checklist, published on the Submittal Checklists page. 92% · county code + published submittal checklist
    • What must be on site at inspection? The permit card and its attached documents, kept accessible from outside the property, plus the recorded Notice of Commencement, plus the modules. Building Department FAQ: 'An official permit card is issued by the Town of Pembroke Park Building Department. The permit card and attached documents shall be available and accessible (outside of the property) to the inspector during all inspections.' Broward application: 'A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION' (required where the contract price exceeds $2,500). At the electrical final, 'The module must be available for inspection.' 88% · department FAQ + permit application + county code
    • Does the inspector verify labels and listings? Yes, explicitly. Broward FBC Ch.1 Sec. 110.3 electrical PV item 10(b) Final: 'The module must be available for inspection. 1. Verify proper labeling. 2. Test system.' Listings and model numbers are checked twice more: at the electrical rough ('Check specifications, model numbers, and layout') and at the building rough (same wording). 94% · county code (FBC Ch.1 amendments)
  5. Sign-off, and permission to operate

    Passing gives you a final or an equivalent sign-off. That is not the same as permission to operate: PTO comes from the utility, and who tells the utility the inspection passed varies. A system left switched off for weeks is usually waiting on this handover.

    • What is issued on pass? A Certificate of Completion for a PV retrofit with no change of occupancy; a Certificate of Occupancy only where occupancy changes. The Town publishes a single 'Certificate of Occupancy / Certificate of Completion Application' and prices them separately: residential CC $35 (minimum $75 per the same line - the schedule contradicts itself), residential CO $75. Underneath that, Broward FBC Ch.1 Sec. 110.3 building item 21 makes the Final Inspection the substantive event and item 22 the Certificate of Occupancy. 68% · department form + fee schedule
    • Who notifies the utility for PTO? The customer or their installer notifies FPL, not the AHJ. FPL: 'All net metering systems require written approval and agreement from FPL' and 'It is highly recommended that customers obtain FPL's written interconnection approval prior to procuring any material'; applications go through FPL's online net metering application with netmetering@fpl.com as the contact. The AHJ's part is a precondition, not a notification: Broward FBC Ch.1 Sec. 110.3 electrical item 11 makes the electrical final the point at which the structure is 'deemed safe for power by the Building Official'. Separately the Town runs a 'REQUEST FOR ELECTRICAL INSPECTION FOR RELEASE OF POWER' process for existing service equipment - explicitly 'NOT AN ELECTRICAL PERMIT'. 65% · utility DG manual + county code
    • Is there a re-inspection fee? Yes, and it escalates. Partial approval or first disapproval of a mandatory inspection $50; second disapproval $100 (2x); third $150 (3x); fourth and subsequent $200 (4x) - per discipline. Code Sec. 5-27(b) is the authority: the inspector notifies the contractor or owner of corrections required, and on re-notification 'the inspector shall again inspect the work or apparatus for a charge as determined in the Building Department Fee schedule.' 78% · ordinance + fee schedule
    • How are corrections issued and cleared? Inspection corrections: Code Sec. 5-27(b) - 'If the building inspector, upon inspection after completion of the work or apparatus, finds that the work does not conform to or comply with the provisions of the state law, the building code, or Town Code Of Ordinances, the inspector shall notify the contractor or owner, indicating the corrections required. When the corrections have been made, the inspector shall be notified by the owner or contractor that the corrections have been made, and the inspector shall again inspect the work or apparatus for a charge.' Plan-review corrections: Broward FBC Ch.1 105.3.1.6 - a local government 'may not request additional information from the applicant more than three times unless the applicant waives such limitation in writing'; where the applicant responds within 30 days the Town must act within 15 days on the first request and 10 days on the second. Resubmittals are made by email to permits@tppfl.gov with a BDTF, ticking 'Corrections (Non-Permitted Plans)'. Fees: second and third residential reviews $45 each, fourth and subsequent disapprovals $180. 85% · ordinance + county code + department form

14 questions answered against Town of Pembroke Park’s own published documents

Q49 How is an inspection booked? Core Booking & scheduling

Email, or phone. The Town instructs 'You must email permits@tppfl.gov to... Request Inspections'. The Building Department page publishes 'Open to Calls for Inspection 8 am to 4 pm' on 954-966-4600. Gov-Easy has a Request Inspection module but the Town warns it does not notify staff, so it is not a working route.

Why the confidence is not higherBoth first-party and current. 88 rather than 95 because the two routes are published on different pages and neither says which is preferred.

department page checked 2026-09-13 https://www.tppfl.gov/194/Online-Permitting-System

Q50 How much notice is required? Core Booking & scheduling

Nothing published by this authority.

Where we lookedHow much notice is required to book an inspection. Searched: the Building Department page (which publishes hours of operation and 'Open to Calls for Inspection 8 am to 4 pm' but no lead time and no cut-off hour for next-day service); the Online Permitting System page (which says to email permits@tppfl.gov to request inspections but states no notice period); the Building Department Document Transmittal Form; the FY2020-21 fee schedule (which prices overtime and re-inspections but states no notice rule); the Forms & Applications page, which publishes no inspection request form at all; and a Town-wide site search for 'inspection request' (299 results, reviewed, none carrying a notice period). Broward's FBC Chapter 1 is silent on notice. This is a genuine publication gap, not an unreachable document.

https://www.tppfl.gov/187/Building-Department

Q51 Are same-day or AM/PM windows offered? Booking & scheduling

No same-day service and no AM/PM window is published. What IS published is the opposite end: 'OVERTIME INSPECTIONS: After hours and/or weekend (per discipline) $250.00 for the first 3 hours; additional hours at $75.00/hr', and a call window of 8 am to 4 pm for booking.

Why the confidence is not higherThis is what the authority publishes, not a statement that windows do not exist. The fee schedule carrying the after-hours line is six years old; the call window is current. A phone call would settle it and was not made.

fee schedule + department page checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/164/New-Fee-Schedule-FY-2020-to-2021-PDF

Q52 Does this AHJ perform its own final solar inspection? Core Who inspects

Yes. The Town performs its own inspections. Its FS 553.80(7)(b) Building Permit & Inspection Utilization Report for FY2024-2025 records 5,143 building inspections and re-inspections requested and 5,143 conducted, of which exactly ONE was conducted by a private provider, with 4 audits of private-provider work, and 7 personnel dedicated to enforcing the Florida Building Code.

Why the confidence is not higherFirst-party statutory report, posted as required. The one-in-5,143 private-provider figure is the cleanest evidence in the file that this is an in-house inspection operation.

FS 553.80(7)(b) report checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/1324/Building-Permits-and-Inspections-Utilization-Report-2025

Q53 If delegated, to whom? Core Who inspects

Not delegated. The optional alternative is FS 553.791 private provider, which is fully operational here: the Town publishes a Private Providers page with a Registration Application Index, Registration and Application Procedures, Forms A-E and Forms R.1-R.3 (including a Private Provider Agreement), and the Broward County Uniform Building Permit Application asks on its face 'Private Provider? YES/NO - If yes, attach Form # 61G20-2.005-2002-01' and 'Per F.S. 553.791(2)(a), do you have the written fee owner's authorization to use a private provider?'

Why the confidence is not higherTen published forms plus the question on the face of the county application. Take-up is near zero (1 of 5,143 inspections in FY2024-25), so the route exists on paper and is barely used in practice.

department page + permit application checked 2026-09-13 https://www.tppfl.gov/339/Private-Providers

Q54 Which inspections are required, and in what order? Core Stages & sequence

Two disciplines, four inspections, in a fixed order, and Broward codifies it. BUILDING (Sec. 110.3 item 20 'Photovoltaic'): (a) Rough - 1. Check specifications, model numbers, and layout; 2. Check attachments, penetrations on the roof, torque requirements; (b) Final. ELECTRICAL (Sec. 110.3 item 10 'Photovoltaic'): (a) Rough, BEFORE MODULES ARE INSTALLED - 1. Check specifications, model numbers, and layout; 2. All wiring for junction boxes, combiner, and inverter completed; 3. Grounding system completed, torque requirements. EXCEPTION: 'The modules for rail-less systems may not require a rough inspection.' (b) Final - the module must be available for inspection - 1. Verify proper labeling; 2. Test system. (c) Service change, if required by the design. THE ORDER RULE: 'The final electrical inspection shall be made prior to the final structural inspection.'

Why the confidence is not higherRe-derived first-hand from the current codified Broward text this run, not inherited. This is the best-specified PV inspection sequence in the Florida survey and it applies to every Broward municipality that adopts the county amendments - which Pembroke Park does at Code Sec. 5-16.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q55 Is a rough-in or mid-roof inspection required? Stages & sequence

Yes, and the electrical rough is scheduled unusually early: 'Rough. Before modules are installed'. The building rough is separate and checks attachments, roof penetrations and torque. The only relief is the rail-less exception: 'The modules for rail-less systems may not require a rough inspection' - note 'may not', which leaves it to the inspector rather than exempting the system.

Why the confidence is not higherVerbatim from the current codified county text. Practically this is the single most schedule-sensitive fact for a Broward PV job: wiring, combiner, inverter and grounding must all be complete and the roof still bare at the electrical rough.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q56 Does the inspector verify labels and listings? Core What is checked

Yes, explicitly. Broward FBC Ch.1 Sec. 110.3 electrical PV item 10(b) Final: 'The module must be available for inspection. 1. Verify proper labeling. 2. Test system.' Listings and model numbers are checked twice more: at the electrical rough ('Check specifications, model numbers, and layout') and at the building rough (same wording).

Why the confidence is not higherVerbatim. 'Verify proper labeling' is the only affirmative label-verification duty found in either corpus, which is why Q38-Q41 are thin while Q56 is strong.

county code (FBC Ch.1 amendments) checked 2026-09-13 https://library.municode.com/fl/broward_county_board_of_rules_and_appeals/codes/the_florida_building_code?nodeId=CH1ADROCO

Q57 Is there a published inspection checklist? Core What is checked

Yes - two of them, at two levels. County: Broward's codified FBC Chapter 1 is itself the checklist, with a dedicated photovoltaic plan-review list (Sec. 107.3.5 structural item A.14 and electrical item B.19) and a dedicated photovoltaic inspection sequence (Sec. 110.3 building item 20 and electrical item 10). Town: the Solar Panels Application Checklist, published on the Submittal Checklists page.

Why the confidence is not higherBoth read in full this run. Caveat worth carrying: the Town's checklist is hosted on Adobe Document Cloud rather than in the Town's own DocumentCenter, which means it does NOT appear in the Town's site search - a search for 'solar' on tppfl.gov returns eleven results and none of them is the solar checklist. An absence booked from that search would have been wrong.

county code + published submittal checklist checked 2026-09-13 https://acrobat.adobe.com/link/review?uri=urn:aaid:scds:US:5d476d3c-f88c-4d87-bd56-0b2b18df6e23

Q58 What must be on site at inspection? Core Documents on site

The permit card and its attached documents, kept accessible from outside the property, plus the recorded Notice of Commencement, plus the modules. Building Department FAQ: 'An official permit card is issued by the Town of Pembroke Park Building Department. The permit card and attached documents shall be available and accessible (outside of the property) to the inspector during all inspections.' Broward application: 'A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION' (required where the contract price exceeds $2,500). At the electrical final, 'The module must be available for inspection.'

Why the confidence is not higherThree first-party sources. Not 95 because no document lists an approved job-set of plans on site, which most Florida authorities require and which a Pembroke Park inspector will almost certainly expect.

department FAQ + permit application + county code checked 2026-09-13 https://www.tppfl.gov/187/Building-Department

Q59 Is there a re-inspection fee? Corrections & re-inspection

Yes, and it escalates. Partial approval or first disapproval of a mandatory inspection $50; second disapproval $100 (2x); third $150 (3x); fourth and subsequent $200 (4x) - per discipline. Code Sec. 5-27(b) is the authority: the inspector notifies the contractor or owner of corrections required, and on re-notification 'the inspector shall again inspect the work or apparatus for a charge as determined in the Building Department Fee schedule.'

Why the confidence is not higherCodified mechanism plus the published rates. Held at 78 because the rate table is the FY2020-21 schedule, six years old, and Sec. 5-27 points at whatever the current Commission-adopted schedule is - which is not posted.

ordinance + fee schedule checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/164/New-Fee-Schedule-FY-2020-to-2021-PDF

Q60 How are corrections issued and cleared? Corrections & re-inspection

Inspection corrections: Code Sec. 5-27(b) - 'If the building inspector, upon inspection after completion of the work or apparatus, finds that the work does not conform to or comply with the provisions of the state law, the building code, or Town Code Of Ordinances, the inspector shall notify the contractor or owner, indicating the corrections required. When the corrections have been made, the inspector shall be notified by the owner or contractor that the corrections have been made, and the inspector shall again inspect the work or apparatus for a charge.' Plan-review corrections: Broward FBC Ch.1 105.3.1.6 - a local government 'may not request additional information from the applicant more than three times unless the applicant waives such limitation in writing'; where the applicant responds within 30 days the Town must act within 15 days on the first request and 10 days on the second. Resubmittals are made by email to permits@tppfl.gov with a BDTF, ticking 'Corrections (Non-Permitted Plans)'. Fees: second and third residential reviews $45 each, fourth and subsequent disapprovals $180.

Why the confidence is not higherFour first-party sources, three of them current. The 'no more than three requests' rule is the one with teeth and it is codified, not advisory.

ordinance + county code + department form checked 2026-09-13 https://library.municode.com/fl/pembroke_park/codes/code_of_ordinances?nodeId=PTIICOOR_CH5BUBURE_ARTIIIFE_DIV1GE_S5-27DOFEREFECEOC

Q61 What is issued on pass? Core Final sign-off & PTO

A Certificate of Completion for a PV retrofit with no change of occupancy; a Certificate of Occupancy only where occupancy changes. The Town publishes a single 'Certificate of Occupancy / Certificate of Completion Application' and prices them separately: residential CC $35 (minimum $75 per the same line - the schedule contradicts itself), residential CO $75. Underneath that, Broward FBC Ch.1 Sec. 110.3 building item 21 makes the Final Inspection the substantive event and item 22 the Certificate of Occupancy.

Why the confidence is not higherThe CC/CO split is inferred from the forms and the fee lines rather than stated for solar. The fee schedule contradicts itself on the CC line ('Certificate of Completion (CC). (Minimum $75.00)' in a row whose residential column reads $35.00). No document says what a solar permit closes out with.

department form + fee schedule checked 2026-09-13 https://www.tppfl.gov/DocumentCenter/View/1295/Certificate-of-Occupancy--Certificate-of-Completion-Application

Q62 Who notifies the utility for PTO? Core Final sign-off & PTO

The customer or their installer notifies FPL, not the AHJ. FPL: 'All net metering systems require written approval and agreement from FPL' and 'It is highly recommended that customers obtain FPL's written interconnection approval prior to procuring any material'; applications go through FPL's online net metering application with netmetering@fpl.com as the contact. The AHJ's part is a precondition, not a notification: Broward FBC Ch.1 Sec. 110.3 electrical item 11 makes the electrical final the point at which the structure is 'deemed safe for power by the Building Official'. Separately the Town runs a 'REQUEST FOR ELECTRICAL INSPECTION FOR RELEASE OF POWER' process for existing service equipment - explicitly 'NOT AN ELECTRICAL PERMIT'.

Why the confidence is not higherNo document in either chain says who transmits the final to FPL. This is assembled from FPL's application requirement plus the county's power-release language, so it is inference from two first-party sources rather than a published statement. Worth a phone call before relying on it. Note also a contamination flavour on the Town's power-release form: its indemnity clause asks the applicant to 'hold Broward County Building Code Division and its employees harmless' - the Town has reused a county form without changing the party.

utility DG manual + county code checked 2026-09-13 https://www.fpl.com/partner/pdf/electric-service-standards.pdf

Lines marked with a percentage were read off this authority’s own published documents. Unmarked guidance is general good practice, not this jurisdiction’s rule — always confirm against the authority before you submit.

No change record for this authority yet. Values arrive here as they are researched, and each one is dated.

Labels & placards for this authority

Wording 85%

No. The Town specifies no placard wording of its own. 'Solar' appears exactly ONCE in the Town's entire 4.27 MB codified corpus and the hit is 'solariums' in a Chapter 15 list of businesses whose employees need identification cards - a new contamination flavour for this survey, alongside 'Solar Flare' and solar reflective index. 'Photovoltaic' appears ZERO times.

Size, colour & material 85%

The Town and county specify nothing. FPL does, and it is unusually specific: 'All labels must be permanent and weatherproof/UV resistant placard with engraved letters. The customer is responsible for all labeling requirements.' Engraved, not printed - that rules out an adhesive label for the two FPL placards.

Where they go 90%

At the interconnecting meter can and at the DER disconnect switch (FPL's two placards), and permanently affixed to the meter enclosure for the battery placard. FPL: 'The following labels must be installed at the interconnecting meter can and the DER disconnect switch.' No AHJ-side placement rule exists at Town or county level.

What the utility wants on top 92%

Yes. FPL Electric Service Standards Section XIII item 6 specifies two placards by exact text, and the battery policy specifies a third: AT THE INTERCONNECTING METER CAN - 'WARNING / MULTI POWER SOURCES / ENTER SOURCES HERE / RATED AC OUTPUT CURRENT ** AMPS / NOMINAL OPERATING VOLTAGE ** VOLTS'. AT THE DER DISCONNECT SWITCH - 'GENERATION SYSTEM AC DISCONNECT / RATED AC OUTPUT CURRENT ** AMPS / NOMINAL OPERATING VOLTAGE ** VOLTS'. AND FOR BATTERY STORAGE - 'A placard must be permanently affixed to the meter enclosure stating "Battery storage utilized in this facility."'

Each figure above is sourced and dated in the full answer set below (questions 38–43). Where an authority’s own published sheet is older than the code it has adopted, the answer says so.

Their website
Solar Requirements
Required placards
Building Department | Pembroke Park, FL Skip to Main Content Create a Website Account - Manage notification subscriptions, save form progress and more. Website Sign In Home Government Departments Building Department Building Department Our Mission Statement We are dedicated to being proactive in serving our residents and business community by providing an experienced administration team implementi
Average approval time — application to PTO

From the CPUC interconnection record. Bars show the average days taken each year; a year with no recorded projects is left blank rather than drawn as zero.

About this authority
Type
Town
County
Broward County
Regions covered
Authority Contact
Building Department
Direct Phone
954-966-4600
Booking & Scheduling